Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsões

AUTOR(ES)
FONTE

IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia

DATA DE PUBLICAÇÃO

2010

RESUMO

The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion¿s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p <0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog¿s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.

ASSUNTO(S)

isoflurane isoflurano nanoemulsões solid-phase microextraction validação : métodos de análise de fármacos validation intravenous nanoemulsion microextração em fase sólida anestésicos high-pressure homogenization general anesthesia

Documentos Relacionados