Newtom
Mostrando 1-10 de 10 artigos, teses e dissertações.
-
1. Comparison of Cone-Beam Computed Tomography and Intraoral Radiography in Detection of Recurrent Caries under Composite Restorations
Resumo A causa mais comum de falha das cáries dentais são as cáries secundárias. Este estudo objetivou comparar a acurácia diagnóstica da radiografia intraoral digital e convencional com a tomografia computadorizada de feixe cônico (TCFC) para a detecção de cáries recorrentes em torno restaurações com compósitos. Cavidades mésio-oclusais-distai
Braz. Dent. J.. Publicado em: 2017-02
-
2. Effect of Time Lapse on the Diagnostic Accuracy of Cone Beam Computed Tomography for Detection of Vertical Root Fractures
Resumo Um diagnostico correto e a tempo das fraturas radiculares verticais (FRVs) é essencial para prevenir extensa perda óssea, tratamentos endodônticos e próteses desnecessárias. O objetivo do presente estudo foi avaliar o efeito do tempo decorrido sobre a acurácia diagnóstica da tomografia computadorizada de feixe cônico (TCFC) para detecção de
Braz. Dent. J.. Publicado em: 2016-02
-
3. Prevalência de calcificações em tecido mole na região mandibular avaliadas por dois sistemas de tomografia computadorizada por feixe cônico
OBJETIVO: Determinar a prevalência de calcificações em tecido mole na região mandibular por meio de análise de imagens axiais provenientes de dois sistemas de tomografia computadorizada por feixe cônico (TCFC), NewTom 3G® e Classic i-Cat®. MÉTODO: Foram avaliadas 246 imagens da região mandibular. Destas, 163 foram adquiridas no aparelho NewTom 3G®
Revista Odonto Ciência. Publicado em: 2011
-
4. Avaliação quantitativa das discrepâncias entre relação cêntrica e máxima intercuspidação, utilizando a tomografia computadorizada volumétrica de feixe cônico
This research has been based on a quantitative evaluation, and has aimed at measuring possible discrepancies between the maxillary (upper jaw) and mandible (lower jaw) positions of Centrical Relation (CR) and Maximum Interspitting (MI), using computed tomography volumetric cone beam (cone method beam).The sample of study has consisted of 20 young adults and
Publicado em: 2009
-
5. Análise quantitativa de modelos de prototipagem rápida baseados em dados de tomografia volumétrica, por meio de inspeção de engenharia reversa tridimensional / Quantitative analysis of rapid prototyping models based on datas of cone beam computerized tomography by inspection of three-dimensional reverse engineering
O objetivo neste estudo foi avaliar a reprodutibilidade quantitativa dos modelos tridimensionais gerados por meio de imagens de tomografia volumétrica de feixe cônico, obtidos por dois tomógrafos volumétricos NEWTOM 9000 DVT (i- (Quantitative Radiology, Verona, Itália) e i-CAT (Imaging Sciencies Int. Hatfield, Pensilvânia. Estados Unidos da América),
Publicado em: 2009
-
6. Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consisted of 10 asymptomatic young adult patients divided into two t
Journal of Applied Oral Science. Publicado em: 2009
-
7. Relatioship between temporomanbular joint space and articular disk position / Relação entre o espaço articular da ATM e a posição do disco articular
Advanced imaging systems, as cone beam computed tomography (CBCT) and magnetic resonance imaging (MRI) have been used for the assessment of the temporomandibular joint (TMJ). Among the pathologies occurring in the TMJ, disk displacement (DD) is one of the most common observed. The aim of this study was to verify condylar position within the fossa in CBCT ima
Publicado em: 2009
-
8. Evaluation of dental tipping achieved in orthodontic treatment with self-ligating brackets using computed tomography images / Avaliação das inclinações dentárias obtidas no tratamento ortodôntico com bráquetes autoligados utilizando tomografia computadorizada
This research had the purpose of evaluating the changes in dental tipping of the anterior teeth of patients treated with self-ligating brackets orthodontic appliances, using computed tomography images. It has been selected a 10-patient clinical sample, all of them presenting complete permanent dentition, either a class I, II or III malocclusion and a 4 mm ma
Publicado em: 2008
-
9. Tomografia computadorizada volumétrica de feixe cônico no estudo da morfologia do canal radicular
Computed tomography, a very important tool in medical diagnostical routine, has been used due to the high quality images it produces, without double images or distortions however its utilization has been restricted due to the high costs and the high levels of radiation that the patient is exposed. A modern type of computed tomography, that uses the cone been
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 13/04/2007
-
10. Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models / "Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem"
The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were p
Publicado em: 2006