Electric Power Distribution Reliability
Mostrando 1-12 de 14 artigos, teses e dissertações.
-
1. Mapping and Characterization of the Grid-connected Photovoltaic Systems in the City of Curitiba: Preliminary Results
ABSTRACT This work presents the mapping of grid-connected photovoltaic systems supported by the Normative Resolution (NR) of the National Agency of Electric Energy (ANEEL) Nº 482/2012 in the city of Curitiba. Firstly, a brief introduction was made justifying the reasons that led to the development of this study, followed by the explanation about the methodo
Braz. arch. biol. technol.. Publicado em: 29/11/2018
-
2. Distributed generators performance during short-circuits considering fault ride-through requirements / Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = : Distributed generators performance during short-circuits considering fault ride-through requirements
The increase of distributed generation penetration in distribution systems not only helps to diversify the electrical matrix but also brings both technical and economic benefits. Yet, it also raises worries related to energy supply reliability. For wind power plants into the medium and high voltage networks there are the grid codes for "Fault Ride-Through" w
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 03/08/2012
-
3. Monitoramento de temperatura do motor de aerogeradores de pequeno porte utilizando Power Line Communication -PLC
The control system and supervision have been revealed very important in product systems. To guarantee the function with quality, industrial process requires a permanent control being necessary keeping stable some variables. One important factor to point using remote monitoring is the possibility to centralize the control of one process in distinct place, man
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 2012
-
4. Metodologia experimental para testes padronizados de confiabilidade em dispositivos indicadores de faltas / Experimental methodology for standardized reliability tests in fault indicator devices
Os dispositivos indicadores de faltas são utilizados para sinalizar a passagem de uma corrente de curto-circuito nos alimentadores de distribuição de energia elétrica. Tais dispositivos permitem uma redução significativa no tempo de inspeção das equipes de manutenção durante a busca pela região faltosa. Entretanto, associada a estes dispositivos,
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 12/12/2011
-
5. Sistema inteligente para alocação eficiente de dispositivos indicadores de falta em alimentadores de distribuição / An intelligent system for efficient allocation of fault indicators in distribution feeders
Fault Indicator (FIs) devices have contributed to improve the location of faults on primary feeders, and consequently the reliability of distribution systems. However, one of the main problems facing their installation in a large scale in a distribution system is the lack of efficient methods to analyze big networks and to pinpoint exactly on which buses the
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 22/08/2011
-
6. UTILIZAÇÃO DA METODOLOGIA AHP PARA ALOCAÇÃO DE EQUIPAMENTOS TELECOMANDADOS EM SISTEMAS DE DISTRIBUIÇÃO PARA MELHORIA DA CONFIABILIDADE / USE FOR AHP METHODOLOGY FOR ALLOCATION OF REMOTELYCONTROLLED DEVICES IN POWER DISTRIBUTION SYSTEMS FOR INCREASE RELIABILITY
In power utilities the subject reliability is a permanent worry. In this new context, some solutions have been developed and researched to an alternative to improve the performance on service restoration when there are consumers without power supply. Among possible solutions the installation of remotely-controlled switches represents a solution that has been
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 22/09/2010
-
7. ELECTRIC DISTRIBUTION POWER SYSTEMS RELIABILITY OPTIMIZATION: An Approach Considering the Selection and Allocation of Protection and Switching Devices / OTIMIZAÇÃO DA CONFIABILIDADE DE SISTEMAS DE DISTRIBUIÇÃO DE ENERGIA ELÉTRICA: Uma Abordagem Considerando a Seleção e Alocação de Dispositivos de Proteção e Manobras
One of the main goals of the electric utilities is to provide energy to its customers in a reliable and low cost way. Traditionally, the electricity sector regulatory commissions impose continuity targets, which must be carried out, to avoid great penalties. For many years, the electric utilities have adopted the practice of allowing the increment of tempora
Publicado em: 2009
-
8. Interferência de harmônicas em equipamentos de medição de energia elétrica. / Harmonic interference in equipment for measurement of eletrical energy.
This work addresses the reliability of energy meters in nonsinusoidal systems, looking for the increase of quality in the electric energy billing. To that purpose, it focuses on a fairer metering and a better relationship between the concessionaire and consumer. The tests were carried through in the laboratories of Eletropaulo, of the Electro-Technology and
Publicado em: 2009
-
9. CaracterizaÃÃo, manutenÃÃo e monitoramento on-line de buchas condensivas para transformadores de potÃncia
According to researches done all over the world about power transformers, the condensives bushings contribute in an expressive way for the percentile distribution of the failure ways related to the power transformers and it is certain to state that occurrences of failures involving bushings have caused damage to the transformers in which these bushings are i
Publicado em: 2008
-
10. Otimização baseada em confiabilidade de planos de manutenção de sistemas de distribuição de energia eletrica / Reliability based optimization of maintenance schedules for electric power distribution systems
Traditional approaches to electric power distribution systems maintenance are based on activities performed at regular intervals, or scheduled after analysis of needs end priorities identified after inspections. Although these maintenances activities are carried out to improve reliability, usually such approaches do not explicitly consider the impact of main
Publicado em: 2007
-
11. PREVISÃO DE DADOS DE ALTA FREQUÊNCIA PARA CARGA ELÉTRICA USANDO HOLT-WINTERS COM DOIS CICLOS / FORECASTING HIGH FREQUENCY LOAD DATA USING A DOUBLE CYCLE HOLT WINTERS APPROACH
The forecast for high frequency data is fundamental for the safety and reliability of the electric power system operation. The methods of exponential smoothing, particularly the Holt-Winters approach and its variations, are appropriate for this type of data due to its highly adaptability and robustness. This work seeks to produce forecasts, every fifteen min
Publicado em: 2007
-
12. Modelo de monitoramento e avaliação da confiabilidade e disponibilidade de sistemas de distribuição de energia elétrica com base nas condições de uso de transformadores. / A monitoring and evaluation model of the reliability and availability of electric power distribution systems based on transformers usage conditions.
This work presents and proposes a model to supervise and evaluate an electrical energy distribution system by applying the usage conditions based maintenance technique on the power and distribution transformers. Monitoring the distribution system transformers with the usage conditions technique allows the system administrator to perform a preventive maintena
Publicado em: 2006