Cooling Towers
Mostrando 1-12 de 36 artigos, teses e dissertações.
-
1. Potencialidade de uso não potável de água de lagoa de detenção
RESUMO As águas de lagoas de detenção geralmente não são utilizadas produtivamente e o seu potencial é desperdiçado. Por estarem disseminadas nas cidades, a utilização dessas águas pode reduzir os custos com transporte de água, além de permitir a preservação de águas de melhor qualidade para fins mais nobres. Algumas das possíveis utilizaçõ
Eng. Sanit. Ambient.. Publicado em: 25/11/2019
-
2. An investigation of virulence factors of Legionella pneumophila environmental isolates
ABSTRACT Nine Legionella pneumophila strains isolated from cooling towers and a standard strain (L. pneumophila serogroup 1, ATCC 33152, Philadelphia 1) were analyzed and compared in terms of motility, flagella structure, ability to form biofilms, enzymatic activities (hemolysin, nucleases, protease, phospholipase A, phospholipase C, acid phosphatase, alkali
Braz. J. Microbiol.. Publicado em: 2018-03
-
3. Projeto e avaliação de desempenho de torres de resfriamento de água utilizando redes neurais artificiais = : Design and analysis of cooling towers using neural netwoks / Design and analysis of cooling towers using neural netwoks
Em muitos processos há necessidade de remover a carga térmica de um dado sistema e utiliza-se, na maioria dos casos, a água como o fluido de resfriamento. Devido à sua crescente escassez e preocupação com o meio ambiente, além de motivos econômicos, a água "quente" que sai desses processos, deve ser aproveitada. Para tanto, ela passa por uma torre d
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/07/2012
-
4. Proposta e comparação de um modelo fenomenológico com base em alto transporte de massa e supersaturação para torre de resfriamento de água. / Presentation and comparison of a model based in high mass transfer and supersaturation in a cooling water tower.
Cooling towers are equipment widely used in industrial plants, where these operate under severe conditions such as cooling water inlet temperatures above 50oC. Under this condition, there are high evaporation of water and high mass transfer, generally not considered in performance analysis of a cooling tower. This work presents and analyzes the differences b
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/12/2011
-
5. Modelagem fenomenológica do desempenho de torres de resfriamento de água acopladas e estudo de casos. / Phenomenological modeling of performance of coupled water cooling towers and case studies.
Neste trabalho foi realizada a modelagem fenomenológica do desempenho de uma torre de resfriamento de água e de um sistema de duas torres de resfriamento em série, com temperatura de água de entrada de até 65 ºC. Verificou-se a validade do modelo através de comparação dos resultados previstos com os obtidos em ensaios em uma unidade piloto. Em segui
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 03/06/2011
-
6. AnÃlise da utilizaÃÃo de gargalos e fios de garrada pet como enchimento de torres de resfriamento
In some industrial processes, as well as in air conditioning processes, there is the need for cooling of equipments that generate heat during his operation. Usually, the fluid utilized to dissipate that generated heat is the water, due to its physical characteristics (high heat capacity, low viscosity, high thermal conductivity and high density). Besides its
Publicado em: 2009
-
7. Valuation of performance of dissolved air flotation on treatment of wastewaters of soybean oil refining / AvaliaÃÃo do desempenho de flotaÃÃo por ar dissolvido no tratamento de efluente de refinaria de Ãleo de soja
The aim of this work was to value the performance of three types of coagulants, two of them of polichlorate of alum class and one of them was organic, combined to three polyelectrolytes class (anionic, cationic and no ionic) applying the dissolved air flotation (DAF), to viability their use on treatment of effluents of soybean oil refinery. The study was con
Publicado em: 2007
-
8. Hydric balance in the Paulinia s refinery and alternatives for water reuse : establishment of an auxiliary tool for the hydric resources management / Balanço hidrico na refinaria de Paulinia e alternativas para reuso de agua : construção de uma ferramenta auxiliar para o gerenciamento dos recursos hidricos
In the last years the shortage of water has been theme of discussions not only in scientific works but also in politics, media and civil society areas, due to the consciousness-raising to this problem worldwide. In Brazil, the metropolitan area of Campinas is among the ones that experience more deeply this kind of problem (DEA = 278.9 3m/year.inhabitant), wh
Publicado em: 2007
-
9. UtilizaÃÃo de materiais alternativos como Enchimento de Torres de Resfriamento
This work studies the behavior of alternative materials as packing for cooling towers. The following materials had been evaluated: vegetal sponge ( Luffa Cylindrica), coconut ( Cocos nucifera Linnaeus) fiber, curlers for hair and necks of PET bottles. In order to investigate the performance of those materials, a prototype of a cooling tower with forced circu
Publicado em: 2006
-
10. THEORETICAL AND EXPERIMENTAL ANALYSIS OF COOLING TOWERS AND AIR WASHERS / ANÁLISE TEÓRICO-EXPERIMENTAL DE TORRES DE RESFRIAMENTO E LAVADORES DE AR
Investigou-se teórica e experimentalmente o comportamento dos equipamentos de transferência de calor e massa conhecidos como Torre de Resfriamento e Lavador de Ar. Para a torre, analisa-se um modelo de simulação, a partir de equações diferenciais ordinárias obtidas através de balanços de energia e massa em um elemento infinitesimal de volume, basead
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 21/09/1988
-
11. Failure of Legionella pneumophila sensitivities to predict culture results from disinfectant-treated air-conditioning cooling towers.
The disinfection of cooling towers based on manufacturers' treatment protocols, as employed in units installed at various public gathering places in Dallas, Tex. (hotels, municipal auditorium), and at the city health department, was evaluated for effectiveness in controlling Legionella pneumophila and compared with previous laboratory studies. In specimens c
-
12. An alkaline approach to treating cooling towers for control of Legionella pneumophila.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favo