METHOD VALIDATION OF ZDDP QUANTIFICATION IN LUBRICATING OIL BY INFRARED SPECTROMETRY / VALIDAÇÃO DO MÉTODO DE ENSAIO DE QUANTIFICAÇÃO DO TEOR DE ZDDP EM ÓLEOS LUBRIFICANTES POR ESPECTROFOTOMETRIA DE INFRAVERMELHO
AUTOR(ES)
VANESSA BREDER VALENTE ZANATTA
DATA DE PUBLICAÇÃO
2009
RESUMO
This study aimed to develop and validate an analytical method for determining the concentration of ZDDP in lubricating oils by infrared spectrometry. We chose to express the concentration of ZDDP based on phosphorus content, due to the need for comparison with analytical techniques that determine the total of this element. The method was able to determine the level of phosphorus by spectrometry in the infrared range from 0.0770 to 0.1500% m/m, this represents around 0.96 to 1.87% m/m of the ZDDP additives studied. Date was obtained with ten scans in absorbance in the range of wave number 1100 - 900 cm-1, resolution 0.5 cm-1, using zinc selenite cell (ZnSe) with 0.10 mm optical path. The analytical curves were constructed using a linear regression by the method of least squares. Real samples were analyzed and the results were compared with those obtained by the technique of ICP-OES. Validation was carried out evaluating the following parameters: specificity and selectivity, working range, linear working range and linearity, sensitivity, accuracy and tendency (bias), accuracy, robustness and uncertainty of measurement. Based on the results were possible to use the methodology in quality control of products whose formulation is composed of ZDDP. Statistical analysis showed that no significant difference between the techniques studied (ICP-OES and IR), considering the range and the products in question. We applied the Student t-test to compare the certified value of the concentration of phosphorus of a MRC with the values obtained using the proposed method. Statistical analysis of results showed that no significant difference between the value of the concentration of phosphorus and the certified value found.
ASSUNTO(S)
oleo lubrificante validacao infrared validation infravermelho lubricating oil
ACESSO AO ARTIGO
Documentos Relacionados
- Espectrofotometria no infravermelho por metodologia FTIR (Fourier Transform Infrared): validação da análise do teor de uréiae de outros parâmetros de qualidade do leite
- Desenvolvimento e validação de um método analítico por espectrofotometria UV para quantificação de carvedilol
- Desenvolvimento e validação de método analítico para quantificação de ácido pfáffico em Hebanthe eriantha
- Desenvolvimento de método analítico para quantificação do efavirenz por espectrofotometria no UV-Vis
- Determinação de contaminantes em óleos lubrificantes usados e em esgotos contaminados por esses lubrificantes