Simulation Methods
Mostrando 25-36 de 737 artigos, teses e dissertações.
-
25. Development and validation a task-specific checklist for a microsurgical varicocelectomy simulation model
ABSTRACT Purpose: To develop and validate a new test of specific technical skills required for microsurgical varicocelectomy. Materials and Methods: An electronic questionnaire was sent to 558 members of the Brazilian Society of Urology for the validation of the task-specific checklist (TSC) for assessment of microsurgical varicocelectomy. Participants who
Int. braz j urol.. Publicado em: 2020-10
-
26. Editorial Comment: Development and validation a task-specific checklist for a microsurgical varicocelectomy simulation model
ABSTRACT Introduction: Transverse preputial island flap urethroplasty (TPIFU) is one of the most frequently performed technique for single-stage repair in proximal hypospadias. It was reported that the subepithelial urethroplasty would obviously decrease urethrocutaneous fistula (UF) complication after proximal TIP. But in the process of TPIFU, it had not b
Int. braz j urol.. Publicado em: 2020-10
-
27. Comparison between traditional project appraisal methods and uncertainty analysis applied to mining planning
Abstract Long-term mining planning is a complex process which involves a large number of variables and uncertainties. Traditional discount cash flow (DCF) is usually used in the evaluation of mining projects. DCF includes net present value (NPV), internal rate of return (IRR), and profitability index (PI). A sensitivity analysis is usually carried out to eva
REM, Int. Eng. J.. Publicado em: 2020-06
-
28. THEORETICAL STUDIES ON DIACETONEDIPEROXIDE DERIVATIVES AND COMPARISONS WITH OTHER MULTI-PEROXIDIC COMPOUNDS
Diacetonediperoxide (DADP) derivatives were investigated with density functional theory (DFT) methods at the DFT-B3LYP and M06-2X/6-311++G (d, p) levels and were also compared with other multi-peroxidic compounds. The investigated derivatives were 3,6-dimethyl-3,6-diamine-1,2,4,5-tetraoxane (DADPNH2), 3,6-dimethyl-3,6-dinitro-1,2,4,5-tetraoxane (DADPNO2), an
Quím. Nova. Publicado em: 2020-06
-
29. Medical Behavior in Cardiorespiratory Arrest before and After Simulation Based on Advanced Cardiac Life Support (ACLS) Course
Abstract Background: The Advanced Cardiac Life Support (ACLS) course is designed to teach cardiovascular emergency, aiming to promote a harmonious and synchronized work of the entire hospital team, making the multidisciplinary job more effective in the execution of cardiopulmonary resuscitation (CPR). Objective: To compare the effectiveness of CPR performe
Int. J. Cardiovasc. Sci.. Publicado em: 2020-04
-
30. Impact of Vacuum-Assisted Venous Drainage on Forward Flow in Simulated Pediatric Cardiopulmonary Bypass Circuits Utilizing a Centrifugal Arterial Pump Head
Abstract Objective: To analyze the impact of vacuum-assisted venous drainage (VAVD) on arterial pump flow in a simulated pediatric cardiopulmonary bypass circuit utilizing a centrifugal pump (CP) with an external arterial filter. Methods: The simulation circuit consisted of a Quadrox-I Pediatric oxygenator, a Rotaflow CP (Maquet Cardiopulmonary AG, Rastatt
Braz. J. Cardiovasc. Surg.. Publicado em: 2020-04
-
31. STUDY OF SOLUBILITY IN SUPERCRITICAL FLUIDS: THERMODYNAMIC CONCEPTS AND MEASUREMENT METHODS - A REVIEW
Abstract Due to the importance of supercritical fluid technology (SFT) in different industries, it has been the subject of intense research in recent decades. Solubility is a key concept in SFT. In fact, obtaining knowledge about the theoretical concepts of solubility and related experimental measurement methods can be useful in developing and improving the
Braz. J. Chem. Eng.. Publicado em: 13/01/2020
-
32. Simulation of Stress Distribution on the Upper First Molar and Alveolar Bone with the Transpalatal Arch and Upper Second Molar Using Finite Element Analysis
Abstract Objective: To evaluate the differences in the stress distribution on the upper first molar with and without transpalatal arch and a second molar when a 150 g force is applied during canine distalization using finite element analysis. Material and Methods: We constructed several models with data obtained by scanning human skulls using cone beam com
Pesqui. Bras. Odontopediatria Clín. Integr.. Publicado em: 13/01/2020
-
33. Avaliação da Competência de Estudantes de Medicina em Identificar Riscos à Segurança do Paciente através de Simulação
RESUMO Introdução A segurança do paciente (SP) está entre os principais temas discutidos pelos profissionais da área de saúde em todo o mundo. No Brasil, em 2016, ocorreram mais de 302 mil mortes por eventos adversos evitáveis e 70% eram de causas preveníveis, que custaram mais de 10,9 bilhões de reais. Objetivo Avaliar os conhecimentos, habilid
Rev. bras. educ. med.. Publicado em: 13/01/2020
-
34. ASSESSMENT OF THE QUALITY OF PEDIATRIC CARDIOPULMONARY RESUSCITATION USING THE IN SITU MOCK CODE TOOL
RESUMO Objetivo: Avaliar a qualidade do atendimento individual e de equipe à parada cardiorrespiratória (PCR) em hospital pediátrico, utilizando a ferramenta de simulação clínica surpresa (in situ mock code). Métodos: Estudo observacional transversal com profissionais de saúde. Foram realizadas simulações clínicas de PCR em diversos setores, em
Rev. paul. pediatr.. Publicado em: 13/01/2020
-
35. Satisfaction and self-confidence in the learning of nursing students: Randomized clinical trial
RESUMO Objetivo: Identificar e comparar a satisfação e autoconfiança na aprendizagem de estudantes de enfermagem a partir do uso da simulação e do ensino tradicional, em cenários de imunização de adultos, no contexto da Atenção Primária à Saúde. Método: Ensaio clínico controlado e randomizado. Participaram do estudo 34 estudantes da gradua
Esc. Anna Nery. Publicado em: 13/12/2019
-
36. AN INVESTIGATION OF THE HEAT TRANSFER PERFORMANCE OF DUAL IMPROVED INTERMIG IMPELLERS IN A STIRRED TANK WITH AN INNER HEATING COIL
Abstract The heat transfer process in a stirred tank of diameter T=0.5m equipped with dual-layer improved Intermig impellers and helical coils was investigated by experiment and numerical simulation methods. The temperature field, the temperature boundary layer lateral to the coil and the heat transfer coefficient were measured at different rotational speeds
Braz. J. Chem. Eng.. Publicado em: 09/12/2019