25. The use of an axisymmetric formulation of the Finite Volume Method for the thermal analysis of the retina and ocular tissues following implantation of retinal prosthesis
This study analyzes the heat transfer in human eyes following implantation of retinal prostheses using an axisymmetric formulation of the Finite Volume Method. The model used consisted of a vertex centered unstructured grid finite volume method in an edge-based data structure and an explicit time integration. The results of the finite volume thermal analysis
J. Braz. Soc. Mech. Sci. & Eng.. Publicado em: 2012-09
-
26. Avaliação in vitro da transmissão de carga oclusal em próteses sobre implantes em função da inclinação de implantes através de análise fotoelástica / In vitro evaluation of occlusal load transmission in prosthetic implant according to the inclination of implants by photoelastic analysis
The All-on-Four technique was conceived in order to decrease the length of the cantilever in the rehabilitation of edentulous patients with implant-supported prosthesis. However, still persist questions related to the biomechanical behavior of implants and the proper technique All-on-Four, since issues such as peri-implant bone loss and failure of the prosth
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 01/09/2011
-
27. Avaliação da deformação média gerada nos intermediários e na região peri-implantar durante as etapas de confecção da prótese parcial fixa parafusada: análise com strain gauges / Evaluation of abutment and simulated bone tissue mean deformation around dental implants, during fabrication stages of screw-retained fixed partial prostheses: strain gauges analysis
A adaptação passiva e estabilidade têm se tornado os dois pré-requisitos de maior importância na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi avaliar, com auxílio dos strain gauges ou extensômetros lineares elétricos, a deformação média ocorrida nos intermediários e na região peri
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/05/2011
-
28. Avaliação de uma máquina de testes de flexão rotacional e seus efeitos em dois sistemas de implante de hexágono externo / Evaluation of a rotating bending machine and its effects on two external hex implant system
O sucesso do tratamento com implantes depende do conhecimento teórico-prático do profissional, das condições biológicas do paciente, e também das propriedades mecânicas dos componentes protéticos e cirúrgicos. A complicação mecânica mais comum é a mobilidade da prótese relacionada ao afrouxamento ou fratura dos parafusos protéticos. Dois teste
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/05/2011
-
29. Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas : efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implants
The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by s
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 15/04/2011
-
30. Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis
OBJECTIVES: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. MATERIAL AND METHODS: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit a
Journal of Applied Oral Science. Publicado em: 2011-12
-
31. Infrapubic approach for malleable penile implant
PURPOSE: Today, we find that the implant of malleable prostheses still plays a leading role in the surgical treatment of erectile dysfunction. These may involve patients for which the cosmetic advantages of inflatable devices are not as important as low cost, the easier use and less incidence of mechanical complications in the malleable implants. This paper
International braz j urol. Publicado em: 2011-02
-
32. Caracterização de polivinilálcool e polivinilpirrolidona (PVAI/PVP) para reparo de cartilagem articular mandibular / Characterization of polyvinylalcohol and polyvinylpyrrolidone (PVAI/PVP) for repair of articular carlilage mandibular
Na área médica, para se desenvolver um dispositivo que funcione como implante, deve-se utilizar materiais que sejam compatíveis para funções específicas do corpo humano, e esses são classificados como biomateriais. Neste trabalho, foram determinados os parâmetros que serão aplicados ao laser de infravermelho (condutividade térmica do material, dens
Publicado em: 2011
-
33. Vibroacustografia na avaliação tridimensional de artroplastia total de quadril / Vibro-acoustography in the tridimensional evaluation of total hip arthroplasty
Vibro-acoustography (VA) is a high lateral resolution (<0.7 mm), speckle-free, non- ionizing and non-invasive image based on the nonlinear combination phenomenon of ultrasound waves (MHz) that generates a narrow focus region of low frequency (kHz). In this work, we propose a VA-based tridimensional evaluation of the exposed area of implants, after total hip
Publicado em: 2011
-
34. Effect of mechanical cycling, material and retorque screws, in stability of complete implant-suported prosthesis with two fit levels / Efeito da ciclagem mecânica, material e retorque de parafusos, na estabilidade de próteses múltiplas sobre implantes com dois níveis de desajuste
O afrouxamento dos parafusos protéticos é frequentemente encontrado nos exames de rotina e pode causar complicações. Assim, métodos para sua prevenção devem ser desenvolvidos. O objetivo neste estudo foi avaliar a influência do retorque de parafusos protéticos (titânio ou ouro) na estabilidade de próteses totais implantossuportadas com diferentes
Publicado em: 2011
-
35. Penile prosthesis implantation in an academic institution in Latin America
PURPOSE: We performed a retrospective study to analyze the effectiveness of implantable penile prostheses in the treatment of erectile dysfunction. MATERIALS AND METHODS: This study included 249 patients who received implants between 2001 and 2008. A total of 139 patients who underwent penile prosthesis implantation were interviewed. RESULTS: Approximately h
International braz j urol. Publicado em: 2010-10
-
36. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis
OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different mic
Journal of Applied Oral Science. Publicado em: 2010-06