Pressure Sensor
Mostrando 37-48 de 79 artigos, teses e dissertações.
-
37. APLICAÇÃO DE MATERIAIS COM MAGNETOSTRICÇÃO GIGANTE EM SENSORES DE DESLOCAMENTO SEM CONTACTO / GIANT MAGNETOSTRICTIVE MATERIALS APPLIED TO CONTACTLESS DISPLACEMENT SENSORS
Magnetostriction is a property of ferromagnetic materials to deform in the presence of a magnetic field. Magnetostriction is an inherent property of magnetic materials, which is unchangeable with time. Materials exhibiting strains in the order of 10-3 are known as giant magnetostrictive materials (GMM).In this dissertation we study the application of these m
Publicado em: 2007
-
38. Sistema colinérgico central modula os ajustes dos sistemas cardiovascular e termorregulatório induzidos pelo exercício físico até a fadiga
ABSTRACT The purpose of this study was to verify if the cardiovascular and thermoregulatory adjustments mediated by central cholinergic receptors and peripheral cathecolamines during the physical exercise until fatigue. Wistar rats weighting 278 ± 5 g, were submitted to bilateral adrenodemedullation (ADM) or sham (SHAM) surgery. After recovery, the animals
Publicado em: 2007
-
39. Avaliação do modelo 5-scale para simular valores de reflectância de unidades de paisagem da floresta nacional do Tapajós / Evaluation of 5-scale model to simulate reflectance values of landscape units of Tapajós national forest
The increased pressure over natural resources makes efficient planning of its use necessary, as well as monitoring and restraining inadequate and/or illegal practices. For this, remote sensing allied with several specialized areas is presented as an excellent tool. However one of the great challenges of remote sensing is to equate the problem that similar ta
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 05/05/2006
-
40. Sensor de pressão microeletronico baseado no efeito piezoMOS / Microelectronic pressure sensor based on the piezoMOS effect
Apresentamos neste trabalho um sensor de pressão de baixo consumo de potência. totalmente compatível com o processo de fabricação CMOS. constituído por um amplificador operacional sensível ao estresse mecânico fabricado sobre uma membrana. O desenho do layout do amplificador é feito de forma a maximizar o efeito do estresse sobre os transistores do
Publicado em: 2006
-
41. DESENVOLVIMENTO DE UM TRANSDUTOR DE PRESSÃO DE ALTA SENSIBILIDADE, BASEADO NO FENÔMENO DE MAGNETOIMPEDÂNCIA GIGANTE, PARA APLICAÇÃO BIOMÉDICA / DEVELOPMENT OF A HIGH SENSITIVITY PRESSURE TRANSDUCER, BASED ON THE PHENOMENON OF GIANT MAGNETOIMPEDANCE EFFECT, FOR BIOMEDICAL APPLICATION
A presente dissertação apresenta o desenvolvimento de um transdutor de pressão de alta sensibilidade, desenvolvido para aplicações biomédicas. O transdutor é baseado em um sensor de magnetoimpedância gigante (MIG), anteriormente desenvolvido, pelo Laboratório de Biometrologia da PUC-Rio. O conhecimento a cerca das principais características do fen�
Publicado em: 2006
-
42. Estudo e especificação de um sistema de instrumentação para unidades de elevação de petróleo utilizando tecnologia sem fio
Wireless sensor networks are reality nowadays. The growing necessity of connectivity between existing industrial plant equipments pushes the research and development of several technologies. The IEEE 802.15.4 LR-WPAN comes as a low-cost and powersaving viable solution, which are important concerns while making decisions on remote sensoring projects. This stu
Publicado em: 2006
-
43. Electronic system for data aquisition, processing and biological signal storage according to standard IEEE 1451.4. / Sistema eletrônico para aquisição, processamento e armazenamento de sinais biológicos baseado na norma IEEE 1451.4.
The purpose of this work was the development of an acquisition, processing and storage system of a signal from an arrangement of sensors based on IEEE 1451.4 standard, resulting in a plug&play sensors system. The acquisition signal system proposed will permit to monitoring several kinds of sensors for a variety application in the fields of biomedical, indust
Publicado em: 2006
-
44. Desenvolvimento de sistema de esterilização por plasma a baixa pressão, usando sistema de acoplamento capacitivo e acoplamento indutivo / Development of plasma sterilization system at low pressure, using capacitive and inductively coupling system
O objetivo deste estudo foi avaliar a eficácia da esterilização por plasma, utilizando como sensor o indicador biológico, esporos deBacillus subtilis. Nesse estudo foram utilizados reatores constituídos de acoplamento capacitivo modo RIE (Reactive Ion Etching) e acoplamento indutivo modo ICP (Inductively Coupled Plasma),sendo esse último classificado e
Publicado em: 2006
-
45. Desenvolvimento de sensor virtual empregando redes neurais para medição da composição em uma coluna de destilação. / Soft sensor development using neural networks for inferential composition in a distillation column.
Soft sensors for composition inference models (that are responsible for the quality) of distillation column products, correspond to virtual instruments implemented in software. This software is able to estimate, in real time, the composition of the output products of the column, based on information such as temperature and pressure on several points of the c
Publicado em: 2005
-
46. SISTEMA DE REGULAGEM DO ESFORÃO DE CORTE EM CHAPAS METÃLICAS COM VARIAÃÃO DE ESPESSURAS / SYSTEM OF REGULATION OF THE CUT EFFORT IN METALLIC PLATES WITH VARIATION IN THICKNESSES
This work presents the project of a system that can be applied under a punching operation with different thickness metal plates and the pressure variation, knowing that is one of the most used process in the mechanical industry conformation, it reaches the most efficient results applied to the studied process. The main is to consider a electropneumatic syste
Publicado em: 2005
-
47. Design and experimental identification of a static and dynamic pressure calibration device / Projeto e identificação experimental de um protótipo de calibrador de pressão estática e dinâmica
A metodologia de projeto e a análise experimental do comportamento dinâmico de um sistema de calibração de pressão são apresentados. A estrutura do calibrador é um vaso de pressão vertical composto de uma estrutura tubular rígida, completamente cheio de líquido, fechado nas extremidades por duas membranas circulares flexíveis. A membrana inferior
Publicado em: 2005
-
48. Estudo da filtração glomerular e da manipulação tubular renal de sodio em animais normotensos e hipertensos submetidos a injeção intracerebroventricular de solução salina hipertonica : influencia da denervação renal bilateral
The mechanism by which blood pressure has risen in the spontaneously hypertensive rats (SHR) strain remains to be elucidated. Besides, there is a surprising lack of experimental data on the natriuretic mechanisms induced by intracerebroventricular (i.c.v.) injection of hypertonic saline in SHR. In the current study, we have hypothesized that SHR hypertension
Publicado em: 2005