Potentiometry
Mostrando 13-24 de 37 artigos, teses e dissertações.
-
13. DETERMINAÇÃO DAS CONSTANTES DE ESTABILIDADE DOS COMPLEXOS FORMADOS ENTRE OS AMINOÁCIDOS CISTEÍNA, N-ACETILCISTEÍNA E LISINA COM CHUMBO EM SOLUÇÃO AQUOSA / DETERMINATION OF STABILITY CONSTANTS FOR LEAD COMPLEXES WITH CYSTEINE, N-ACETYLCYSTEINE AND LYSINE IN AQUEOUS SOLUTIONS
In this study we investigated the interaction between lead and the amino acid cysteine, lysine and N-acetylcysteine by testing long-term contact with ion exchanger resins and also the determination of stability constants. The importance of investigating the presence of lead in solutions for parenteral nutrition is related to the risk of internal contaminatio
Publicado em: 2011
-
14. Preparo de amostras de combustíveis fósseis por piroidrólise para a determinação de flúor e cloro
Pyrohydrolysis is proposed for fossil fuels sample preparation for further fluorine and chlorine determination. Samples were heated during 10 min at temperatures up to 1000 °C. Water vapor was passed through the reactor and the volatile products were condensed and collected in NH4OH solution. Fluoride was determined by potentiometry using an ion selective e
Química Nova. Publicado em: 2010
-
15. STUDY OF BINARY COMPLEXES OF ALUMINUM(III) WITH SULFUR AMINO ACIDS AND PHOSPHATE LIGANDS / ESTUDO DE COMPLEXOS BINÁRIOS DE ALUMÍNIO(III) COM AMINOÁCIDOS SULFURADOS E LIGANTES FOSFATADOS
The study of binary complexes of Al(III) with sulfur amino acids (methionine, cysteine, homocysteine and penicillamine) and phosphate ligands (adenosine 5 - triphosphate and phosphocreatine) was done in aqueous solution applying potentiometric titrations, (13)C and (27)Al NMR, Raman spectroscopy, molecular modeling and DFT: B3LYP/6-311G theoretical calculati
Publicado em: 2010
-
16. Determination of protonation constants of some tetracycline antibiotics by potentiometry and lc methods in water and acetonitrile-water binary mixtures
Uma estimativa acurada das constantes de dissociação de antibióticos tetraciclina em misturas binárias acetonitrila-água é muito importante para muitas técnicas de separação, como cromatografia líquida e eletroforese capilar que usam essas misturas de solvente. Neste estudo, os valores de pKa de cinco tetraciclinas (tetraciclina, oxitetraciclina, c
Journal of the Brazilian Chemical Society. Publicado em: 2009
-
17. ANÁLISE QUÍMICA DO LIXIVIADO DA ÁGUA DE XISTO EM UM LATOSSOLO VERMELHO ESCURO DISTRÓFICO
Industrial processes generate a series of products, often without applicability becomes waste that contribute to pollution of soil, air and water. Some products may be reused and / or processed into raw materials for other processes. In this context, analyzed the water of oil shale (a byproduct of the process of obtaining the oil shale) using an Instrumental
Publicado em: 2009
-
18. GRANTS FOR GROUNDWATER MANAGEMENT AT SANTA MARIA RIVER BASIN/RS / SUBSÍDIO PARA GESTÃO DAS ÁGUAS SUBTERRÂNEAS NA BACIA HIDROGRÁFICA DO RIO SANTA MARIA/RS
This study aims to provide subsidies for groundwater management at the basin of Rio Santa Maria-BHRSM. Located in the southwest of Rio Grande do Sul state, Brazil, on the edge of Paraná Basin and transitioning towards the Uruguaio Sul-Riograndense Shield, has an area of 15,797,300 square kilometers. About 16 formations occur in outcrops Pavão (2004), of wh
Publicado em: 2009
-
19. Determinação da atividade da pectina metilesterase em pectinases industriais e a atividade residual exógena no suco da manga
As pectinases, um grupo de enzimas que degradam substâncias pécticas e rompem ligações glicosídicas, são produzidas por fungos filamentosos, leveduras e bactérias, mas encontram-se também em plantas em geral e em frutas, em particular. Na indústria de sucos as enzimas pectinolíticas são adicionadas para aumentar o rendimento do processo, diminuir
Publicado em: 2009
-
20. Protein decorated Nanoparticules : Small Unilamellar Lipid Vesicules and Block Copolymers Micelles. / Nanoparticules Décorées par des Protéines : Vésicules Lipidiques Unilamellaires et Micelies à Base de Copolymères à Blocs
The formation of protein Annexin-A5 decorated (bio-functionalized) nanoparticles is of particular interest in micelle-mediated target drug delivery, in vivo magnetic resonance imaging, or controlled fabrication of biochips. This work describes an easy access to the synthesis and manipulation of block copolymer nano-objects exhibiting binding ability for the
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 03/07/2008
-
21. Determinação de ascarel em óleo isolante de transformadores
The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniq
Química Nova. Publicado em: 2007-06
-
22. Emprego do sal di-sódico de edta como padrão no preparo de soluções
The hydrated sodium salt of EDTA, Na2H2Y·2H2O, cannot be used as a primary standard for titrations due to uncertainties in the water content. An alkalimetric titration of the homogenized solid in the presence of a small excess of BaCl2·2H2O allows one to titrate quantitatively the released two hydrogen cations with end-point indication by phenolphthalein o
Química Nova. Publicado em: 2007-06
-
23. Potentiometric investigation of oscillating reaction for the determination of ascorbic acid by perturbation of the oscillation pattern / Estudo potenciométrico de reações oscilantes para a determinação de ácido ascórbico, por perturbação do padrão de oscilação
Neste trabalho, é proposta a determinação de ácido ascórbico em amostras de medicamentos, utilizando-se um sistema potenciométrico, desenvolvido no laboratório que permitiu o estudo de reações oscilantes. Esse método baseia-se na determinação de ácido ascórbico utilizando como princípio o efeito desta substância no padrão de oscilação da r
Publicado em: 2006
-
24. Caracterização potenciométrica simultânea em fluxo, de espécies aniônicas, empregando análise das componentes principais e redes neurais artificiais / Simultaneous potentiometric characterization in flow, with anionic species, using principal components analysis and artificial neural networks
Foi montado um sistema potenciométrico composto por 6 eletrodos seletivos à íons (ISE) de brometo, iodeto, nitrato, nitrito, sulfeto e cianeto. Os seis eletrodos foram colocados em linha, permitindo fazer determinações potenciométricas em fluxo contínuo. As variáveis, o controle de fluxo e a estabilização das leituras foram verificados através de
Publicado em: 2006