Plasmon Resonance
Mostrando 1-12 de 283 artigos, teses e dissertações.
-
1. Device for Streptavidin Detection Using LSPR and Electrochemical Transductions on the same Platform
Research in biosensing currently occupies an important role among biomolecular detection techniques, especially with respect to medical diagnoses. Is this sense, the development of biosensors based on the localized surface plasmon resonance (an optical transducer) or electrochemical transductions have been highlighted. However, optical and electrochemical de
J. Braz. Chem. Soc.. Publicado em: 2021-04
-
2. PHOTODEGRADATION OF RhB UNDER VISIBLE LIGHT BY PT/TIO2 NANOPARTICLES PREPARED THROUGH PHOTOREDUCTIVE DEPOSITION PROCESS
Pt/TiO2 nanoparticles were prepared by a simple two-step aqueous solution method, which consists of a low temperature hydrothermal step and a photoreduction deposition step. The as-prepared samples were characterized by XRD, TEM, XPS, UV-vis, and BET techniques. The as-prepared samples exhibited enhanced photocatalytic activity towards the degradation of rho
Quím. Nova. Publicado em: 2021-03
-
3. Characterization of Otto Chips by Particle Swarm Optimization
Abstract Recently a surface plasmon resonance (SPR) optical sensor, based on the Otto configuration — the Otto chip — has been developed. One essential step in the quality control of the fabrication process is characterization of the active region of several devices in a batch. Characterization is done by measuring the angular spectrum of the optical re
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2021-03
-
4. Activated Complex Approach to Describe Bovine Serum Albumin-Azure A and Bovine Serum Albumin-Azure B Intermolecular Interactions
Azure A (AZA) and azure B (AZB) phenothiazine dyes are used for clinical and medical purposes, and their functions can be altered via interactions with proteins. However, no kinetics information on the interactions between phenothiazine dyes and bovine serum albumin (BSA) is available. Surface plasmon resonance was used to determine the energetic and dynamic
J. Braz. Chem. Soc.. Publicado em: 2020-12
-
5. New Strategy for Streptavidin Detection Using AuNRs/PAAm Hydrogel Composites
Localized surface plasmon resonance (LSPR) is a collective oscillation of free electrons induced by the incident light in nanometric surfaces of conductive materials. Gold nanorods (AuNRs) have been studied for plasmonic devices due to their anisotropic properties. Herein, we report the construction of a specific biosensor using polyacrylamide (PAAm) as the
J. Braz. Chem. Soc.. Publicado em: 2020-09
-
6. DEVELOPMENT OF AN ANALYTICAL METHOD FOR THE DETERMINATION OF LEAD BASED ON LOCAL SURFACE PLASMON RESONANCE OF SILVER NANOPARTICLES
Lead is environmental pollutant that even in low trace is harmful for human health and wildlife. In this study we presented a colorimetric method for determination of Pb2+ in water by aggregation of silver nanoparticles capped citrate in the presence of deferoxamine as chelating agent. Silver nanoparticles were prepared by reduction of AgNO3 with NaBH4. In t
Quím. Nova. Publicado em: 2020-06
-
7. METHOD DEVELOPMENT AND VALIDATION FOR THE FLUOROQUINOLONES DETERMINATION BY STABILIZED SILVER NANOPARTICLES
Silver nanoparticles (AgNPs) stabilized with glutathione (GSH) were used as nanosensors for the determination of fluoroquinolones such as ciprofloxacin (CIP), norfloxacin (NOR) and enrofloxacin (ENRO) in aqueous systems. The AgNPs were stabilized with GSH (Ag-GSH NPs), whereas the decrease of the surface plasmon resonance (SPR) band at 400 nm and the bathoch
Quím. Nova. Publicado em: 2020-03
-
8. BIOSSENSORES PLASMÔNICOS BASEADOS EM ESPALHAMENTO RAMAN INTENSIFICADO POR SUPERFÍCIE UTILIZANDO NANOBASTÕES DE OURO
There is still a significant need for low cost, fast and trustworthy diagnostic devices based on biosensors, which may impact positively for applications in developing countries. Localized surface plasmon resonance (LSPR) based biosensors have been taken as powerful alternative to deal with the above limitations. The local electromagnetic field enhancement c
Quím. Nova. Publicado em: 05/12/2019
-
9. Determination of cefotaxime, cefoperazone, ceftazidime and cefadroxil using surface plasmon resonance band of silver nanoparticles
The aim of this work is to evaluate simple, sensitive, effective and validated procedures for the determination of cefotaxime, cefoperazone, ceftazidime and cefadroxil. In this study, the methods based on the ability of the cited drugs to reduce Ag+ ions to silver nanoparticles (Ag-NPs) in the presence of Polyvinyl Pyrrolidone (PVP) as a stabilizing agent pr
Braz. J. Pharm. Sci.. Publicado em: 29/11/2018
-
10. Alternagin-C binding to α2β1 integrin controls matrix metalloprotease-9 and matrix metalloprotease-2 in breast tumor cells and endothelial cells
Abstract Background Matrix metalloproteinases (MMPs) are key players in tumor progression, helping tumor cells to modify their microenvironment, which allows cell migration to secondary sites. The role of integrins, adhesion receptors that connect cells to the extracellular matrix, in MMP expression and activity has been previously suggested. However, the m
J. Venom. Anim. Toxins incl. Trop. Dis. Publicado em: 24/05/2018
-
11. New trends in plasmonic (bio)sensing
Abstract The strong enhancement and localization of electromagnetic field in plasmonic systems have found applications in many areas, which include sensing and biosensing. In this paper, an overview will be provided of the use of plasmonic phenomena in sensors and biosensors with emphasis on two main topics. The first is related to possible ways to enhance t
An. Acad. Bras. Ciênc.. Publicado em: 2018
-
12. Femtoliter Scale Detection of an Antithyroid Drug Using Gold Nanoparticles in a Microfluidic Chip
Sensitive detection of methimazole (MMI) at the femtoliter (fL) scale has been achieved based on photo thermal lensing of gold nanoparticles (GNPs). GNPs were used because their surface plasmon resonance (SPR) have absorption in visible range. A combined glass microfluidic chip-photo thermal lens microscopy (MFC-PTLM) system with appropriate laser source was
J. Braz. Chem. Soc.. Publicado em: 2017-10