Optical Interferometer
Mostrando 1-12 de 16 artigos, teses e dissertações.
-
1. Optical Fiber Spool Acoustic Wave Resonances Employing a Mach-Zehnder Interferometer in Vacuum Chamber
Abstract The longitudinal, flexural, and torsional modes of acoustical resonances are presented for a long and small thickness cylindrical fiber spool. The fiber spool is built using a monomode optical fiber tightly wound in a helix form around a cylindrical Styropor. The acoustical resonance values are obtained using a Mach Zehnder interferometer with the f
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-12
-
2. Estudo do desempenho do Multiplexador/Demultiplexador add/dropbaseado na configuraÃÃo do InterferÃmetro de Michelson de fibras Ãpticas para aplicaÃÃes em sistemas OTDMA e OCDMA / Study the performance of the multiplexer/demultiplexer add/drop based on the Michelson interferometer configuration for fiber for applications in optical systems OTDMA and OCDMA
Neste trabalho, alÃm dos capÃtulos que envolvem a teoria e definiÃÃes, foi basicamente divido em trÃs estudos: Primeiro (capÃtulo 4), apresentamos uma investigaÃÃo numÃrica do desempenho de um filtro passa-banda totalmente Ãptico composto por um acoplador direcional duplo seguido de duas grades de Bragg simetricamente iguais gravadas nos seus braÃ
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 02/03/2012
-
3. Estudo numÃrico da influÃncia da relaxaÃÃo da nÃo-linearidade Kerr e aplicaÃÃes com portas lÃgicas utilizando PAM em componentes de fibras Ãpticas: interferÃmetro de Sagnac e acoplador direcional / Numerical study of the Kerr nonlinearity relaxation influence and aplications with logic gates using PAM in optical fiber devices: Sagnac interferometer and nonlinear directional coupler
Neste trabalho de Tese, foram investigadas caracterÃsticas de operaÃÃo de dois dispositivos Ãpticos, o InterferÃmetro de Sagnac (NOLM) e o Acoplador Direcional NÃo- Linear (NLDC) Duplo SimÃtrico. Com o primeiro dispositivo, trabalhando com pulsos de 10ps , o que equivale a uma largura espectral em banda de 0,1 THz , em duas diferentes aplicaÃÃes: es
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 29/11/2011
-
4. Study and compensation of bias drift, scale factor stability and linearity of a conditioning and sign processing circuit of an interferometric fiber optic gyroscope / Estudo e compensação da deriva termica, estabilidade do fator de escala e lineariazação de um circuito de condicionamento e processamento de sinais de girometro interferometrico a fibra optica
Fiber Optic gyroscopes are an important part of inertial navigation systems. To meet the necessary specifications required for application in inertial systems, it is mandatory that the electronic Sagnac demodulator uses state of the art devices. The proposal of this work is to study and develop a technique to correct all together for the nonlinearities, the
Publicado em: 2009
-
5. New technique for the implementation of digital demodulation of fiber optic gyroscopes / Implementação de uma nova tecnica para demodulação digital de sinal de giroscopio a fibra optica
Gyroscopes are devices used to measure angular orientation, being extensively employed for guidance, navigation and stabilization. Among the many types of gyroscopes, IFOG (Interferometer Fiber Optic Gyroscope), based on Sagnac effect, is the most interesting solution due to its high sensitivity, resolution, reliability, small size and EMI immunity. The pres
Publicado em: 2009
-
6. Study of the fabrication steps of an electro-thermo-optical device using Mach-Zehnder interferometer. / Estudo das etapas de fabricação de dispositivos eletro-termo-ópticos utilizando o interferômetro Mach-Zehnder.
In this work, a study of the steps to fabricate an electro-thermo-optical device is realized. This device is based in a Mach-Zehnder interferometer (IMZ) where a micro-resistor is placed in one of the IMZ arms. The Mach-Zehnder interferometer was fabricated using Anti-Resonant Reflecting Optical Waveguide (ARROW) where oxinytride and amorphous hydrogenated s
Publicado em: 2008
-
7. Implementação de sensores ópticos integrados para aplicações em análises químicas e ambientais. / Implementation of integrated optical sensors for chemical analysis and environment aplications.
The aim of this work is the development of optical chemical sensors based on Mach-Zehnder Interferometer (MZI) for chemical and environmental analysis applications. Such devices were implemented with waveguides fabricated on a silicon substrate. The waveguides were obtained using silicon nitride (Si3N4) and silicon oxide (SiO2) films obtained by CVD (Chemica
Publicado em: 2007
-
8. Fabricação e caracterização de Guia de Onda Polimerica a base de PMMA modificado por plasma de CHF3 / Polymeric optical waveguides fabricated by plasma fluorination process
Polymeric optical devices have been studied in communication and interconnection optics due to the intrinsic versatility of polymers molecular structure, that allows advantageous refractive index modeling for core and cladding, and also to their easy fabrication process or patterning capability. PMMA, polymethylmetacrylate, shows the best optical properties
Publicado em: 2007
-
9. TÃcnicas de Interferometria Ãptica aplicada à medicina, odontologia e comunicaÃÃes Ãpticas
In the work described in this thesis, we used two different interferometric techniques, the coherent optical frequency domain reflectometry (COFDR), and the optical coherence tomography (OCT). Both techniques are based on the Michelson interferometer. They were applied to optical communications and to medical and dentistry imaging. We will give a general des
Publicado em: 2006
-
10. Desenvolvimento de um sistema de imageamento usando a tomografia por coerÃncia Ãptica no domÃnio temporal e de Fourier
In this dissertation, we describe the basic theory and details of the implementation of three experimental optical coherence tomography systems, two in the time domain and one in the spectral (Fourier) domain. Optical coherence tomography (OCT) is a non invasive optical imaging method, capable of producing cross-sectional images of materials and biological t
Publicado em: 2006
-
11. Estudo de interferência de elétrons em dispositivos mesoscópicos no limite Hall quântico
In this work we introduce the basic concepts required to understand how electronic interferometers work. The interferometers are semiconductor devices based in GaAs/AlGaAs heterojunctions where a high mobility two-dimensional electron gas is formed. The electron gas is confined in a small region of dimension comparable to its Fermi wavelength. In a high magn
Publicado em: 2006
-
12. AvaliaÃÃo da interface dente/restauraÃÃo no esmalte dental utilizando-se a tÃcnica de tomografia por coerÃncia Ãptica e os mÃtodos tradicionais
The integrity of tooth/restoration interface is very important for the success of dentistry treatment. The evaluation of this site can be done using visual and tactile inspection, which can be helped by the use of radiographic exams. These diagnosis methods, however may not show all the information needed for a final and sound diagnosis. For this reason, alt
Publicado em: 2005