Novapex
Mostrando 1-7 de 7 artigos, teses e dissertações.
-
1. Effect of pre-flaring and file size on the accuracy of two electronic apex locators
OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and
J. Appl. Oral Sci.. Publicado em: 2012-10
-
2. Influence of pulp condition on the accuracy of an electronic foramen locator in posterior teeth: an in vivo study
The aim of this study was to assess, in vivo, the accuracy of the NovApex® electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex®was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex® locator and confirmed using
Brazilian Oral Research. Publicado em: 24/02/2012
-
3. Ex vivo accuracy of three electronic apex locators using different apical file sizes
Este estudo avaliou a precisão de três localizadores eletrônicos foraminais (Root ZX, Novapex e Justy II) nas determinações de odontometria utilizando limas com diferentes padrões de ajuste, considerando-se a constrição apical (CA) e do forame principal (FA) como referências anatômicas. O diâmetro dos forames apicais de 40 dentes unirradiculados f
Brazilian Dental Journal. Publicado em: 2012
-
4. Efeitos do pré-alargamento na acurácia de três localizadores apicais eletrônicos
OBJETIVO: Comparar três localizadores apicais eletrônicos (LAEs) e avaliar a influência do pré-alargamento cervical na sua acurácia. MÉTODOS: O comprimento de trabalho (CT) de trinta incisivos inferiores humanos extraídos foi determinado visualmente. Todos os dentes foram montados em um meio condutor e testados com Novapex, Mini Apex Locator e Propex
Revista Odonto Ciência. Publicado em: 2011
-
5. Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators / Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais
This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root c
Publicado em: 2005
-
6. Analise comparativa, in vitro, da eficiencia na odontometria de tres localizadores apicais (Root ZX, Bingo 1020 e Novapex)
A presente pesquisa teve por finalidade avaliar, in vitro, a eficácia dos localizadores apicais, Bingo 1020, Novapex e Root ZX, nas posições 1mm aquém do ápice e na posição 0 (zero). Comparar a odontometria eletrônica na posição 0 com a medida real dos dentes. Comparar a odontometria radiográfica com a odontometria eletrônica utilizando o Bingo 1
Publicado em: 2005
-
7. AvaliaÃÃo clÃnica da precisÃo de um localizador apical / Clinical evaluation of the accuracy of a electronic apex locator
Esta pesquisa teve como objetivo avaliar In Vivo a PrecisÃo de um localizador apical Novapex (Forum Technologies, Tel Aviv – Israel) que funciona com duas freqÃÃncias dependentes. Foram utilizados 63 incisivos centrais divididos em 3 grupos (A, B and C) respectivamente (polpa viva, polpa necrosada sem reaÃÃo periapical visÃvel radiograficamente e
Publicado em: 2004