Metrological Reliability
Mostrando 1-12 de 24 artigos, teses e dissertações.
-
1. Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
ABSTRACT Electromagnetic and ultrasonic flowmeters are high precision devices that can measure the water flow in pressurized irrigation networks. In these networks, the inadequate installation distance of flow control valves generates upstream disturbances which will increase measurement errors and reduce the accuracy of the equipment. Therefore, estimating
Sci. agric. (Piracicaba, Braz.). Publicado em: 04/11/2019
-
2. An investigative case study at local hospital into the current reliability of blood pressure sphygmomanometers
Abstract Introduction Arterial Blood Pressure is a significant indicator of the current health condition of an individual. The correct detection of hypertension is essential, where this health problem is considered as one of the greatest health risks factors that affect the heart and circulatory system. This paper presents the importance of the application
Res. Biomed. Eng.. Publicado em: 06/04/2017
-
3. Análise dos procedimentos e critérios de implantação de feixes de raios X de referência ISO 4037 em baixas energias
According to the radiological protection principles, practices involving ionizing radiation must be planned and carried out under the guarantee that the values of individual doses, the number of people exposed to radiation and the probability of accidental exposures are as low as reasonably achievable. Therefore, radiation dosimetry is required to be done wi
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 09/08/2012
-
4. METROLOGICAL RELIABILITY OF BLOOD COLD CHAIN EQUIPMENTS / CONFIABILIDADE METROLÓGICA DE EQUIPAMENTOS DA CADEIA DE FRIO PARA PRODUTOS HEMOTERÁPICOS
A confiabilidade metrológica dos equipamentos da cadeia de frio para conservação de produtos hemoterápicos é fundamental para garantir a eficiência de tratamentos e evitar a ocorrência de eventos adversos. Os freezers utilizados para conservação do sangue e hemocomponentes devem atender aos requisitos exigidos pela Portaria número 1.353, publicada
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 19/09/2011
-
5. METROLOGICAL RELIABILITY OF THE ANALYTICAL METHOD BY X-RAY FLUORESCENCE FOR STEEL INDUSTRY MATERIALS / CONFIABILIDADE METROLÓGICA NA DETERMINAÇÃO DE ESPÉCIES QUÍMICAS EM MATERIAIS SIDERÚRGICOS POR ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X
O objetivo da dissertação é avaliar a confiabilidade metrológica da técnica de fluorescência de raios-X utilizada em análises quantitativas de espécies químicas presentes em materiais siderúrgicos utilizados na produção do aço. O estudo da técnica e a avaliação da capacidade do equipamento analítico associado às etapas de recebimento, prepa
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 08/06/2011
-
6. Interferência de harmônicas em equipamentos de medição de energia elétrica. / Harmonic interference in equipment for measurement of eletrical energy.
This work addresses the reliability of energy meters in nonsinusoidal systems, looking for the increase of quality in the electric energy billing. To that purpose, it focuses on a fairer metering and a better relationship between the concessionaire and consumer. The tests were carried through in the laboratories of Eletropaulo, of the Electro-Technology and
Publicado em: 2009
-
7. STUDY OF THE METROLOGICAL RELIABILITY OF SPHYGMOMANOMETERS / ESTUDO DA CONFIABILIDADE METROLÓGICA DE ESFIGMOMANÔMETROS
Observa-se um crescente interesse na determinação da incerteza de medição para a avaliação de conformidade e garantia da qualidade, principalmente nos setores de meio- ambiente, segurança, saúde e indústria, nos quais o resultado da medição é considerado crítico por lidar diretamente com seres humanos. Na medição da pressão arterial, conforme
Publicado em: 2008
-
8. METROLOGICAL ASSESSMENT OF FLUORESCENCE SIGNALS OF MEASUREMENTS OF PIGMENTS IN WATER / AVALIAÇÃO METROLÓGICA DA RESPOSTA DE SINAIS DE FLUORESCÊNCIA PARA MEDIÇÕES DE PIGMENTOS EM ÁGUA
Aim. Providing reliability of LIDAR readings of fluorescence signals for measurements of pigments in ocean water by: (i) establishing configuration standards for equipment parameters. (ii) assessing different procedures to improve the signal-tonoise relationship. (iii) preserving the integrity of the wavelength bandwidth of the fluorescence spectrum. (iv) ve
Publicado em: 2007
-
9. O enfoque da metrologia química em análises toxicológicas na atividade turfística: validação de método analítico para determinação de cafeína em matrizes biológicas
This paper proposes an alternate method to detect forbidden doping substances present in biological matrices of horseracing. The method was fully validated for caffeine, identified as the most frequent forbidden substance in the analysis conducted by the Antidoping Laboratory of the Brazilian Jockey Club, which adopts a zero threshold limit according to nati
Química Nova. Publicado em: 2007
-
10. Desenvolvimento e avaliação de padrão de torque para calibração de torquímetros em três faixas de medição
The continuous development of instruments and equipment used as tools or torque measurement in the industry is demanding more accurate techniques in the use of this kind instrumentation, including development of metrological characteristics in torque measurement. The same happens with the needs in calibration services. There is a diversity of methods of hand
Publicado em: 2007
-
11. CONFIABILIDADE METROLÓGICA DA SUPERVISÃO DE VAZÃO EM SISTEMA DE RESFRIAMENTO A ÁGUA EM USINAS HIDRELÉTRICAS / METROLOGICAL RELIABILITY OF FLOW RATE MEASUREMENT IN HYDROELECTRICAL COOLING WATER SYSTEM
A supervisão da vazão da água de resfriamento em equipamentos de produção de energia de usinas hidrelétricas tem sido uma questão de preocupação devido à possibilidade de obstrução dos equipamentos de medição pela água sem tratamento. Outrossim, por razões econômicas, um instrumento barato e confiável deve ser escolhido para os vários pont
Publicado em: 2007
-
12. METROLOGICAL RELIABILITY OF LASER AND INTENSE PULSED LIGHT ELECTROMEDICAL EQUIPMENT / CONFIABILIDADE METROLÓGICA DE EQUIPAMENTOS ELETROMÉDICOS A LASER E A LUZ INTENSA PULSADA
Para lançar equipamentos eletromédicos no mercado brasileiro, é necessária a obtenção de registro da Agência Nacional de Vigilância Sanitária, que tem por requisito a apresentação da certificação de conformidade. Na presente dissertação foram realizados estudos dos documentos normativos necessários para a avaliação da conformidade de equipa
Publicado em: 2007