Fast Recovery
Mostrando 13-24 de 324 artigos, teses e dissertações.
-
13. SEQUENTIAL MULTI-ELEMENT DETERMINATION OF TRACE-METALS IN BIODIESEL SAMPLES USING HR-CS FAAS
In this work the feasibility of sequential multi-element determination of Zn, Fe, Mg, Cu, Na, K, Cr, Al and Ca in biodiesel samples by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was investigated. Biodiesel samples obtained from different sources and different chemical processes were analysed. The samples were diluted w
Quím. Nova. Publicado em: 2021-02
-
14. DETERMINAÇÃO DE FÓSFORO EM PALEOSSEDIMENTOS EMPREGANDO ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X PORTÁTIL
Phosphorus (P) is an important chemical marker of the past human presence, because, besides indicates the localization of possible archaeological sites, also, contributes to clarify doubts regarding to origin, duration and to specific functions that were developed in them. The present study aimed to obtain a simple, accurate, fast and non-destructible analyt
Quím. Nova. Publicado em: 2021-02
-
15. Exploring Polypyrrole as Extraction Phase for Disposable Pipette Extraction Method for Multiclass Organic Micro-Pollutant Determination in River and Tap Water Using Gas Chromatography-Mass Spectrometry
The use of a polypyrrole (PPy) is described as an efficient extraction phase for disposable pipette extraction (DPX), in a fast and ruggedized analytical method for simultaneous determination of 18 organic micro-pollutants in water using gas chromatography-mass spectrometry (GC-MS). The DPX-blank pipettes were filled with PPy, a material produced through the
J. Braz. Chem. Soc.. Publicado em: 2020-10
-
16. Use of Arduino in the Development of a New and Fast Automated Online Preconcentration System Based on Double-Knotted Reactor for the Mn Determination in Tea Samples by Flame Atomic Absorption Spectrometry (F AAS)
In the present paper, an automated online preconcentration system based on the use of two knotted reactors (KR) was developed for Mn determination in tea samples by flame atomic absorption spectrometry (F AAS). The system automation was performed by using four solenoid valves to switch sample streams and reagents. Valves were driven electronically by an inte
J. Braz. Chem. Soc.. Publicado em: 2020-01
-
17. Classificação de fragmentos florestais urbanos com base em métricas da paisagem
Resumo A urbanização no município de Campinas-SP e região ocorreu de forma rápida e intensa, provocando acentuadas alterações na paisagem e resultando em uma expressiva degradação das áreas florestais e da cobertura vegetal natural. Este fenômeno deu origem a um processo de fragmentação florestal bastante intenso. Neste contexto, mapear estes fr
Ciênc. Florest.. Publicado em: 02/12/2019
-
18. Comparison of sperm selection techniques in donkeys: motile subpopulations from a practical point of view
Abstract The aim of this study was to compare the post-thaw distribution of motile sperm subpopulations, following simple or colloid centrifugation. A new analysis was used to evaluate the available number of sperm from each subpopulation after each centrifugation protocol. Frozen/thawed semen samples were divided into the following after-thawing treatments:
Anim. Reprod.. Publicado em: 25/11/2019
-
19. REVISITING THE NUCLEOPHILICITY CONCEPT IN A COMPREHENSIVE BIOMASS VALORIZATION EXPERIMENT: FROM PAPAYA SEEDS TO THIOUREA MOTIFS
The recovery of waste materials with potential for synthetic transformations is a major field in science. However, just few experiments have been devoted to undergraduate students by exploring some consistent subjects in light of simple, natural resources. Nucleophilicity is a central subject in chemistry and there are significant synthetic models to exploit
Quím. Nova. Publicado em: 21/10/2019
-
20. Factors affecting urinary continence and sexual potency recovery after robotic-assisted radical prostatectomy
ABSTRACT Introduction Robot-assisted radical prostatectomy (RARP) is the most recent surgical technique for localized prostate cancer. The Da Vinci (Intuitive Surgical, Sunnyvale, CA) system was first introduced in Brazil in 2008, with a fast growing number of surgeries performed each year. Objective Our primary endpoint is to analyze possible predictors
Int. braz j urol.. Publicado em: 02/09/2019
-
21. Jejum pré-operatório abreviado favorece realimentação pós-operatória com menor custo de internação hospitalar em pacientes oncológicos.
RESUMO Objetivo: avaliar a viabilidade de abreviação do jejum em cirurgias colorretais oncológicas, bem como, o impacto no desfecho cirúrgico dos pacientes. Métodos: estudo prospectivo comparativo randomizado com pacientes submetidos à cirurgias eletivas colorretais, por câncer, no período de maio a setembro de 2017. Os pacientes foram randomizados
Rev. Col. Bras. Cir.. Publicado em: 05/08/2019
-
22. Effect of Processing Parameters on Hot Deformation Behaviour and Microstructural Evolution of PM Ti-5553 Alloy at a Moderate-high Strain Rate
Isothermal compression tests of Ti-5553 (Ti-5Al-5V-5Mo-3Cr) alloy, produced by a fast consolidation approach from blended elemental powder mixture, were performed on a Gleeble® 3800 thermal-physical simulator to investigate its hot deformation behaviour. The samples were compressed in a wide temperature range from 700 ºC to 1150 ºC and a moderate-high str
Mat. Res.. Publicado em: 10/06/2019
-
23. Anesthetic quality and cardiovascular and respiratory effects of continuous intravenous infusion of tiletamine-zolazepam in bitches
RESUMO: Objetivou-se avaliar a qualidade e a recuperação da anestesia promovida pela associação tiletamina-zolazepam, administrada por via intravenosa (IV) contínua, em cadelas pré-medicadas com acepromazina. Foram utilizadas oito cadelas, sem raças definidas, clinicamente sadias, pesando em média 13,7±1,9kg. Após jejum alimentar de 12 horas e híd
Pesq. Vet. Bras.. Publicado em: 2019-03
-
24. Fit-for-Purpose ICP-MS Procedure Supporting Brazilian Regulations on Inorganic Constituents in Fresh and Saline Waters
This work aimed the development of an analytical procedure using inductively coupled plasma mass spectrometry (ICP-MS) in four modes of operation for simple and fast determination of Al, Ag, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Na, Ni, Pb, Sb, Se, Tl, Hg, V, U, and Zn in fresh and sea water samples attending simultaneously four Brazilian regula
J. Braz. Chem. Soc.. Publicado em: 2018-07