Electromagnetic Coils
Mostrando 1-11 de 11 artigos, teses e dissertações.
-
1. Optimization Techniques and Mathematical Modeling Applied to Reluctance Motors
Abstract The present work aims at the application of different optimization strategies in the electromagnetic analysis of the Variable Reluctance Motor (VRM) through Finite Element (FE) simulation. Two case studies are investigated: the first one aims to optimize the geometry and electrical characteristics of windings of a single-phase VRM 6/6, minimizing co
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
2. Growth rates of dynamic dermal model exposed to laminar flow and magnetic fields
Abstract Introduction Ongoing research in the use of electromagnetic stimulation as coadjuvant in fracture healing has led the authors to begin generating computer models in order to predict cellular growth changes when cells are electromagnetically stimulated. By generating these models, scientists will be able to better understand how electromagnetic fiel
Res. Biomed. Eng.. Publicado em: 18/03/2016
-
3. Exposure to 50 Hz electromagnetic field changes the efficiency of the scorpion alpha toxin
AbstractBackground Extremely low-frequency (50 Hz) electromagnetic field (ELF-EMF) is produced by electric power transmission lines and electronic devices of everyday use. Some phenomena are proposed as “first effects” of ELF-EMF: the discrete changes in the membrane potential and the increase of the calcium channel activity as well as the intracellular
J. Venom. Anim. Toxins incl. Trop. Dis. Publicado em: 20/10/2015
-
4. Detection of acute cerebral hemorrhage in rabbits by magnetic induction
Acute cerebral hemorrhage (ACH) is an important clinical problem that is often monitored and studied with expensive devices such as computed tomography, magnetic resonance imaging, and positron emission tomography. These devices are not readily available in economically underdeveloped regions of the world, emergency departments, and emergency zones. We have
Braz J Med Biol Res. Publicado em: 2014-02
-
5. Desenvolvimento de sistema eletrônico para tomografia de indução magnética / Electronic system development for magnetic induction tomography
Magnetic induction tomography is a contactless conductivity imaging technique. This technique uses a magnetic field generator (usually a coil) to induce Eddy currents in the target object and several magnetic sensors (usually coils as well) that capture the magnetic field generated by these induced currents. The measurements obtained by these sensors can be
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 29/08/2011
-
6. Single layer cylindrical and helicoidal coil with voids between successive turns electromagnetic field calculation to be used in superconductor current limiter simulator for design purpose
A very accurate mathematical method, named Helicoidal Method, to calculate the flux density vector B produced by the current circulating in the resistive single-phase superconductor electrical current limiter (RSCL) coils, at any point of the its whole space, using the Biot-Savart’s Law is presented in this paper. It is very important to remember that thes
Publicado em: 2011
-
7. Evaluation of the normal force of a planar actuator
This paper describes a method to compute the normal force that acts on the mover of an electromagnetic planar actuator. The method is based on the Maxwell Stress Tensor and depends on the resulting magnetic field. The actuator has a mover with two permanent magnets and a ferromagnetic stator covered by two orthogonal armature coils. The mover is hold by a su
Publicado em: 2011
-
8. Optimization of saddle coils for magnetic resonance imaging
In Nuclear Magnetic Resonance (NMR) experiments, besides the apparatus designed to acquire the NMR signal, it is necessary to generate a radio frequency electromagnetic field using a device capable to transduce electromagnetic power into a transverse magnetic field. We must generate this transverse homogeneous magnetic field inside the region of interest wit
Brazilian Journal of Physics. Publicado em: 2006-03
-
9. Construção de um sistema experimental para desaceleração de átomos. / Construction of an experimental system for stopping atoms.
This work presents the development and test of an experimental set-up which allows to produce a very strong slow motion atomic beam. We discuss the calculation and construction of the solenoid to compensate the Doppler effect arising during the deceleration process, vacuum chambers, the oven which produces the atomic beam and the optical system used. We have
Publicado em: 1991
-
10. Effect of Contour Shape of Nervous System Electromagnetic Stimulation Coils on the Induced Electrical Field Distribution
BioMed Central.
-
11. A NEW PRINCIPLE FOR ELECTROMAGNETIC CATHETER FLOW METERS*
An electromagnetic catheter flow meter is described in which the magnetic field is generated by two parallel bundles of wire carrying equal currents in opposite directions. The electrodes are fixed centrally to the insulated wire bundles that generate the magnetic field. The flow sensor is flexible, resembling a split catheter. The flow transducer is designe