Calorimeter
Mostrando 13-24 de 73 artigos, teses e dissertações.
-
13. Determination of crystallization kinetics parameters of a Li1.5Al0.5Ge1.5(PO4)3 (LAGP) glass by differential scanning calorimetry
Crystallization kinetics parameters of a stoichiometric glass with the composition Li1.5Al0.5Ge1.5(PO4)3 were investigated by subjecting parallelepipedonal samples (3 × 3 × 1.5 mm) to heat treatment in a differential scanning calorimeter at different heating rates (3, 5, 8 and 10 °C/min). The data were analyzed using Ligero's and Kissinger's methods to de
Mat. Res.. Publicado em: 16/04/2013
-
14. Physicochemical properties of poly(lactic acid-co-glycolic acid) film modified via blending with poly(butyl acrylate-co-methyl methacrylate)
A series of poly(lactic acid-co-glycolic acid) (PLGA)/poly(butyl acrylate-co-methyl methacrylate) (P(BA-co-MMA)) blend films with different P(BA-co-MMA) mole contents were prepared by casting the polymer blend solution in chloroform. Surface morphologies of the PLGAP(BA-co-MMA) blend films were studied by scanning electron microscopy (SEM). Thermal, mechanic
Polímeros. Publicado em: 2013
-
15. Estudo sobre a identificação de hádrons em câmaras de fotoemulsão / Study about hadron identification in emulsion chambers
This work introduces the importance of photoemulsion chambers that remain in use after decades and still offer many advantages for elementary particle physics. We cite OPERA (Oscillation Project with Emulsion-tRacking Apparatus) detector that is the greatest lead photoemulsion chamber detector ever constructed as an example of its application nowadays (nine
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 16/04/2012
-
16. Properties of experimental resins based on synthesized propoxylated bis-GMA with different propionaldehyde ratios
The effect of different propionaldehyde ratios on the properties of bis-GMA-based comonomers and copolymers diluted with propoxylated bis-GMA (CH3bis-GMA) was evaluated. Five experimental comonomers were prepared combining bis-GMA with CH3bis-GMA and propionaldehyde at 0, 2, 8, 16, 24 mol%. Light polymerization was effected with the use of 0.2 wt. (%) each o
Materials Research. Publicado em: 05/04/2012
-
17. Influência da adição de hardfats sobre as propriedades tecnológicas do óleo de palma visando a aplicação em chocolates / Influence of the addition of hardfats on technological properties of palm oil aiming the application in chocolate
Palm threes (Elaesis guineensis) are one of the main sources of industrial vegetable oils. Palm oil, extracted from the pulp of the fruit is widely used in the food industry, as for instance, in the production of chocolates. However, in many applications the amount of palm oil added is restricted by its preferential ß - polymorphism, slow crystallization ra
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/09/2011
-
18. RECEPÇÃO DO SINAL DE MÚONS NO CALORÍMETRO HADRÔNICO DO EXPERIMENTO ATLAS
Neste trabalho são realizados estudos sobre a recepção do sinal de múons de um calorímetro hadrônico de altas energias, utilizado para absorção e medição da energia das partículas hadrônicas provenientes das colisões de feixes de prótons no experimento LHC (Large Hadron Collider), no CERN. Estes estudos visam o desenvolvimento de um sistema par
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 24/03/2011
-
19. Efeito de metais de transição sobre a polarização espontânea na estrutura cristalina de nanopós da família tungstênio bronze
This work aimed the study of the effect of transition metals (Ni, Fe, Co) on the spontaneous polarization of the ferroelectric oxides of tetragonal tungsten bronze (TTB)-type structure of potassium strontium niobate (KSr2Nb5O15) and of the KSr2(FeNb4)O15-d, KSr2(NiNb4)O15-d and KSr2(CoNb4)O15-d solid solutions. All systems investigated were prepared by mecha
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/02/2011
-
20. Usando um calorímetro isoperibólico no laboratório didático de uma forma diferente / Using an isoperibol calorimeter at didactical laboratory in a different way
Esse trabalho consiste na utilização de um calorímetro isoperibólico em laboratório didático de química no nível superior, para se estudar aspectos mais amplos de alguns processos, que não os energéticos. Como se sabe, o calorímetro é o principal instrumento da primeira lei da termodinâmica e, como tal, presta-se, normalmente, para se obter a va
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 16/07/2010
-
21. Calorímetro de gelo: uma abordagem histórica e experimental para o ensino de química na graduação
In addition to the usual advantage of an ice calorimeter of being able to measure slow heat changes, the instrument described here is extremely simple to construct and operate. Specific heat of aluminum, copper, lead and tin metals were determined using the ice calorimeter made with easily accessible materials. The values obtained from specific heat are near
Química Nova. Publicado em: 2010
-
22. Padronização do gasto metabólico de repouso e proposta de nova equação para uma coorte feminina brasileira / Standardization of resting metabolic rate and proposal of a new equation for a Brazilian female cohort
A obesidade tem aumentado de maneira epidêmica em todo mundo. Independente da sua causa básica, um desequilíbrio no balanço energético está sempre envolvido. Sendo assim, o cálculo adequado das necessidades energéticas do paciente é de grande importância. Diversos estudos evidenciam que as fórmulas comuns para estimativa do gasto metabólico de re
Publicado em: 2010
-
23. Caracterização de uma liga NiTi visando confecção e aplicação como material biomédico em órtese Grampo de Judet
No presente trabalho foi feito estudo em ligas metálicas comerciais de NiTi , chapa atuador tipo M com 0,5 mm de espessura e liga 3M termoativada , fio com 0,48mm X 0,64mm referência 4297-919, com secção transversal retangular, afim de caracterizar material a ser utilizado no ciclo operacional de fabricação do grampo de Judet. . Para a caracterização
Publicado em: 2010
-
24. Construção de um calorímetro isotérmico diferencial de alta sensibilidade e baixo custo
The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes the construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 μL. The calorimeter was built using two small high sensibility square Peltier thermoelectric sens
Química Nova. Publicado em: 2009