Pulse pressure variation and stroke volume variation under different inhaled concentrations of isoflurane, sevoflurane and desflurane in pigs undergoing hemorrhage
AUTOR(ES)
Oshiro, Alexandre Hideaki, Otsuki, Denise Aya, Hamaji, Marcelo Waldir M., Rosa, Kaleizu T., Ida, Keila Kazue, Fantoni, Denise T., Auler Jr, José Otavio Costa
FONTE
Clinics
DATA DE PUBLICAÇÃO
2015-12
RESUMO
OBJECTIVES: Inhalant anesthesia induces dose-dependent cardiovascular depression, but whether fluid responsiveness is differentially influenced by the inhalant agent and plasma volemia remains unknown. The aim of this study was to compare the effects of isoflurane, sevoflurane and desflurane on pulse pressure variation and stroke volume variation in pigs undergoing hemorrhage. METHODS: Twenty-five pigs were randomly anesthetized with isoflurane, sevoflurane or desflurane. Hemodynamic and echocardiographic data were registered sequentially at minimum alveolar concentrations of 1.00 (M1), 1.25 (M2), and 1.00 (M3). Then, following withdrawal of 30% of the estimated blood volume, these data were registered at a minimum alveolar concentrations of 1.00 (M4) and 1.25 (M5). RESULTS: The minimum alveolar concentration increase from 1.00 to 1.25 (M2) decreased the cardiac index and increased the central venous pressure, but only modest changes in mean arterial pressure, pulse pressure variation and stroke volume variation were observed in all groups from M1 to M2. A significant decrease in mean arterial pressure was only observed with desflurane. Following blood loss (M4), pulse pressure variation, stroke volume variation and central venous pressure increased (p<0.001) and mean arterial pressure decreased in all groups. Under hypovolemia, the cardiac index decreased with the increase of anesthesia depth in a similar manner in all groups. CONCLUSION: The effects of desflurane, sevoflurane and isoflurane on pulse pressure variation and stroke volume variation were not different during normovolemia or hypovolemia.
Documentos Relacionados
- Minimum alveolar concentrations and hemodynamic effects of two different preparations of sevoflurane in pigs
- VELOCITY OF BLOOD FLOW AND STROKE VOLUME OBTAINED FROM THE PRESSURE PULSE *
- Pulse Pressure Variation Patterns in a Swine Model of Hypovolemia under Spontaneous Breathing vs. Invasive Positive-Pressure Ventilation
- Cerebrospinal fluid pulse pressure and intracranial volume-pressure relationships.
- Comparison of vena cava distensibility index and pulse pressure variation for the evaluation of intravascular volume in critically ill children