Evaluation of an indirect fluorescent-antibody stain for detection of Pneumocystis carinii in respiratory specimens.

AUTOR(ES)
RESUMO

Two prospective studies were undertaken to evaluate a commercial indirect fluorescent-antibody (IFA) stain for the detection of Pneumocystis carinii in respiratory specimens from individuals at risk for or with the acquired immunodeficiency syndrome. The first study compared IFA with Diff-Quik (DQ; a rapid Giemsa-like stain) for detecting P. carinii in 95 induced sputa obtained from 77 asymptomatic patients who had survived one previous episode of P. carinii pneumonia and who were being treated prophylactically with aerosolized pentamidine. Only one induced sputum specimen was found to contain P. carinii; organisms were detected by both stains. The second study compared the performance of the IFA stain versus DQ, modified toluidine blue O, and Gomori methenamine silver stains for detecting P. carinii in symptomatic individuals at risk for or with acquired immunodeficiency syndrome. Of 182 specimens examined, P. carinii was detected in 105 by one or more stains; the DQ stain detected 73 (70%), the modified toluidine blue O stain detected 75 (71%), the Gomori methenamine silver stain detected 76 (72%), and the IFA stain detected 95 (90%). The IFA stain was more sensitive (P less than 0.01) than the other traditional stains for detecting P. carinii; however, a subsequent clinical evaluation revealed that a subset of IFA-positive-only specimens were from patients whose clinical symptoms resolved without specific anti-P. carinii therapy.