Modified indirect fluorescent-antibody test for aspergillosis.
AUTOR(ES)
Gordon, M A
RESUMO
Diffuse fluorescence in an indirect fluorescent-antibody test for antibody to Aspergillus fumigatus was eliminated by using germlings, rather than hyphae, as antigen. The modified method yielded diagnostic titers larger than or equal to 1:32 in 24 of 25 known cases, was highly specific, and showed good correlation with clinical status and results of immunodiffusion. This technique, which uses the germling antigen, inactivation of test serum at 59 +/- 1 degrees C, and anti-immunoglobulin G conjugate, is a sensitive, specific, and reliable quantitative indicator of aspergillosis and is useful in following the course of the disease.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=274725Documentos Relacionados
- Automation of the Indirect Fluorescent-Antibody Test for Toxoplasmosis
- Comparison of an enzyme-linked immunoassay and a quantitative indirect fluorescent-antibody test with the conventional indirect fluorescent-antibody test for detecting antibodies to Toxoplasma gondii.
- Use of isolated nuclei in the indirect fluorescent-antibody test for human cytomegalovirus infection: comparison with microneutralization, anticomplement, and conventional indirect fluorescent-antibody assays.
- Comparison between a modified counterimmunoelectrophoresis test and the indirect fluorescent-antibody test for detection of antibodies to rabies virus in human sera.