Avaliação das alterações dimensionais em modelos de gesso para protese total por meio de medição tridimensional em função de materiais e tecnicas de moldagem / Avaliation of dimensional changes in complete dentures stone cast by means of tri-dimensional measurements, in relation to materials and impression methods

AUTOR(ES)
DATA DE PUBLICAÇÃO

2005

RESUMO

The purpose of this study was to analyze, through three-dimensional measurements, the dimensional changes in casts of stone used to make complete dentures, in function of different materials for impression: addition reaction silicone, alginate and impression compound reline with alginate. The casts of stone type IV were made from molds obtained from a metallic standard die of aluminum. In this metallic die were put seven screws with 3,5mm diameter, to establish referential points of the measured distances. The referential points allowed creating segments for the calculation of the area and volume in the representative drawings generated for the stone casts. The procedure allows evaluating the dimensional stability through three-dimensional measurements. In CETEF the stone die were measured with three-dimensional equipment Mitutoyo, model BLN 710, equipped with measurement head Renishaw PH9 and feeler TP200 with sphere of 1mm of diameter, for the stages: 1- Transfer of the three-dimensional coordinates for the program Mechanical Desktop; generation of the two-dimensional drawings; measurement of the segments that compose each drawing; generation of the three-dimensional drawings; projected area determination and volume calculation using the finite elements net; making of a calculation spread sheet for each impression material; statistical treatment of the data and mathematical determination of the variations in the x, y and z coordinates in the lengths of each segments, in the perimeters and in the areas of each drawing of the forty five casts. 2 - Insertion of the data in the calculation spread sheets; statistical treatment of the data and mathematical determination of the variations and in the x, y and z coordinates in the lengths of each one of the segments, in the perimeters and of the areas of each drawing. 3 - Three-dimensional presentation of the dimensional variations found in the models; transfer of the variations of the coordinates of the group of models of each material, for the software of 3D drawing ? Mechanical Desktop; generation of the drawings for visualization of the variations and elaboration of technical report. The results were submitted to the simple mathematics medium of the dispersion or variation of the data, that it is the degree, in which the numeric data of the sample tend to disperse around a medium value. It was used in this work the calculation of the simple standard deviation. The molds made with addition reaction silicone produced casts with smaller dimensional variation, when compared to the casts obtained with alginate or impression compound reline with alginate. The silicone presented larger capacity to repeat generated copies of the molds, from the standard die. The cast made with addition reaction silicone presented small variation among themselves when compared to the standard metallic die

ASSUNTO(S)

dentures moldagem dentaria complete materiais dentarios protese dentaria completa dental impression materials

Documentos Relacionados