Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.
AUTOR(ES)
Bancroft, K
RESUMO
The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=239334Documentos Relacionados
- Growth and persistence of pathogens on granular activated carbon filters.
- Production and characterization of granular activated carbon from activated sludge
- Assessment of the bacteriological activity associated with granular activated carbon treatment of drinking water.
- Bacterial Growth in Mixed Cultures on Dissolved Organic Carbon from Humic and Clear Waters
- Effects of Surface Area and Flow Rate on Marine Bacterial Growth in Activated Carbon Columns