Analysis of data from digital intraoral spectrophotometer of two dental porcelain after different surface treatments / Análise dos dados obtidos com o uso do espectrofotômetro digital intraoral de duas porcelanas dentais após diferentes tratamento de superfície
AUTOR(ES)
Angela de Caroli
DATA DE PUBLICAÇÃO
2009
RESUMO
Considering the current aesthetic aspect, the harmony between the color of the tooth and dental restorative materials is one of the issues of greatest importance and technical difficulty. The use of apparatus for the selection of color by digital method proposes to reduce the subjective aspect of the vision of colors, thus minimizing possible failures of the process. This study simulated clinical situations in three prosthetic ceramic pieces in the form of three surface treatments, a scattering using silicon carbide bur, a cold glaze and an overglaze in ceramic oven. Then we evaluate the interference of the treatments on the color of the two porcelains, with and without the presence of saliva using the objective method of color matching, with the aid of a digital intraoral spectrophotometer. It was concluded that there was no change in color perceptible to the human eye of any material on the surface treatments carried out, however, there is a greater change in color for the treatment overglaze when compared to other treatments; the difference in color caused by the presence of saliva in the Noritake and the values found for all treatments in Duceram were visible to the human eye trained on color selection; the treatment overglaze on porcelain Duceram caused the highest E , reaching the acceptable limit; in the presence of saliva values of E increased for Noritake and decreased for Duceram, indicating that the different compositions of materials can alter their behavior; the difference between measurements with and without saliva for Noritake porcelain is more evident than for Duceram; the device is deficient in some interpretations, but is acceptable for the clinical use of color matching; the equipment is not indicated for color matching in scientific studies; the analysis of the data La*b* are not consistent with the readings of the color tabs Vita Classical and 3D Master.
ASSUNTO(S)
porcelain cor spectrophotometer espectrofotômetro color porcelana
Documentos Relacionados
- Shear bond strength of ceramic brackets after different pre-treatments in porcelain surface
- ANÁLISE DE DIFERENTES PROCESSOS SUBTRATIVOS UTILIZADOS NO TRATAMENTO DA SUPERFÍCIE DE IMPLANTES ODONTOLÓGICOS DE TITÂNIO CP
- Avaliação da resistência ao cisalhamento da zircônia após diferentes tratamentos de superfície
- Accuracy of intraoral and extraoral digital data acquisition for dental restorations
- Ceramic characterization and factography of resin-ceramic adhesive interface after different ceramic surface treatments