Analog To Digital Converter
Mostrando 1-12 de 21 artigos, teses e dissertações.
-
1. ELECTRICAL NOISES REDUCTION IN NANOPORES EXPERIMENTS BASED ON CONSENSUS FILTER
Nanopore has developed into an indispensable tool for single molecules experiments, where useful information about the characteristics of DNA/RNA can be obtained from the flowing of ionic current elicited by individual molecules as they traverse a single nanometer-scale aperture. However, due to the relatively high background current noise and low measuremen
Quím. Nova. Publicado em: 20/07/2020
-
2. A study of strain and deformation measurement using the Arduino microcontroller and strain gauges devices
Abstract This paper presents a methodology for the measurement of strain by means of strain-gauges, where the data acquisition is done by using an Arduino Uno board, due to the low-cost and the easy manipulation of this microcontrollers. The measured signal conditioning is performed by means of a Wheatstone Bridge and then discretized by an Analog-Digital Co
Rev. Bras. Ensino Fís.. Publicado em: 10/12/2018
-
3. Novel Design of Photonic Digital Sensors for Distinguishing Uniformly-Distributed Refractive Indices of Fluids
Abstract The authors propose a novel structure of k-level (k is an arbitrary integer) photonic digital sensor based on directional couplers with specific structural parameters. Its function is similar to an analog-to-digital converter (ADC) in electronic system, and capable of distinguishing 2k+1-1 discrete and uniformly-distributed refractive indices of the
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2018-03
-
4. Hardware embedded fiber sensor interrogation system using intensive digital signal processing
The description of an interrogation system for fiber Bragg grating sensors is reported. The full implementation in hardware of the required signal processing is proposed and made publicly available. The hardware description is implemented in a field programmable gate array (FPGA) development kit and the processing units allow one to control an optoelectronic
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2014-12
-
5. DESENVOLVIMENTO DE UM CONVERSOR A/D INTEGRADOR COM FAIXA DE ENTRADA E RESOLUÇÃO PROGRAMÁVEL A CAPACITOR CHAVEADO / DEVELOPMENT OF AN A / D CONVERTER INTEGRATOR WITH TRACK OF ENTRY AND PROGRAMMABLE RESOLUTION TO SWITCHED CAPACITOR
Circuitos integrados programáveis possibilitam o seu ajuste após a fabricação, para se adequarem a mais de uma aplicação dentro de um conjunto determinado de aplicações. Um sistema de medição programável pode ser aplicado em medições que envolvam um conjunto de sensores com características diferentes de sinais e um conversor analógico-digital.
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 13/04/2012
-
6. Estudo clínico e eletromiográfico de músculos cervicais em mulheres com e sem disfunção temporomandibular / Clinical and electromyographic study of cervical muscles in women with and without temporomandibular dysfunction
The temporomandibular disorder (TMD) among many symptoms causes orofacial pain. It is also common, the incidence of neck pain complaint, which leads to overlapping signs and symptoms of temporomandibular joint (TMJ) and cervical spine. This study aimed to compare the patterns of electromyographic activity and the presence and severity of pain in the cervical
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/08/2011
-
7. Projeto de um conversor analógico-digital para um receptor Bluetooth em tecnologia CMOS. / Analog to digital converter design for a Bluetooth receiver in CMOS technology.
In this work, an Analog to Digital Converter (ADC) fulfilling the Bluetooth standard specifications is designed. This block stays at the reception side of an integrated wireless transceiver in CMOS technology. Initially, an analysis of the ADC as a system is carried out, at the same time that the specifications at that level are developed. The architecture a
Publicado em: 2010
-
8. CONVERSOR ANALÓGICO-DIGITAL INTEGRADOR A CAPACITOR CHAVEADO COM FAIXA DE ENTRADA PROGRAMÁVEL / INTEGRATED DIGITAL-ANALOG CONVERTER A CAPACITOR KEY WITH PROGRAMMABLE INPUT RANGE
Circuitos integrados programáveis possibilitam o seu ajuste após a fabricação, para se adequar a mais de uma aplicação dentro de um conjunto determinado de aplicações. Esses circuitos são flexíveis, mas podem perder em desempenho quando comparado a outro circuito fabricado para servir a apenas uma aplicação específica. Um sistema programável po
Publicado em: 2010
-
9. Metodologia para descrição de células analógicas como IP
This work proposes a methodology for the description of analog and mixed-signal VLSI cells as intellectual property (IP) blocks. The methodology was applied on analog/mixed-signal circuitry blocks - a voltage-to-current converter and an analog-to-digital converter, previously designed in CMOS technology - as study cases. Adaptations were performed in the blo
Publicado em: 2009
-
10. UTILIZAÇÃO DE Microsternarchus bilineatus (OSTARIOPHYSI, GYMNOTIFORMES, HYPOPOMIDAE) COMO BIOMONITOR: O EFEITO DE COMBUSTÍVEIS AUTOMOTIVOS DERIVADOS DO PETRÓLEO NA DESCARGA DO ÓRGÃO ELÉTRICO
This study evaluated the effect of automotive fuel (gasoline and diesel) on the Electric Organ Discharge (EOD) frequency of Microsternarchus bilineatus (Ostariophysi, Gymnotiform), with the objective of testing the viability of this species as a biomonitor to detect pollutant derived from petroleum. Ten individuals of the species were exposed to concentratio
Publicado em: 2008
-
11. Computerized invasive measurement of time-dependent intraocular pressure
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability
Brazilian Journal of Medical and Biological Research. Publicado em: 2006-09
-
12. Automatic system for thermal damage detection in manufacturing process with internet monitoring
This work involved the development of a smart system dedicated to surface burning detection in the grinding process through constant monitoring of the process by acoustic emission and electrical power signals. A program in Visual Basic® for Windows® was developed, which collects the signals through an analog-digital converter and further processes them usi
Journal of the Brazilian Society of Mechanical Sciences and Engineering. Publicado em: 2006-06