28/07/2016

Oxygen uptake, respiratory exchange ratio, or total distance: a comparison of methods to equalize exercise volume in Wistar rats

This study compared strategies to equalize the volume of aerobic exercise performed with different intensities by Wistar rats, based on the distance covered during exercise bouts and energy expenditure (EE, isocaloric sessions) obtained from oxygen uptake (V̇O2) or respiratory exchange ratio (RER). Thirty-three male rats (270.5±12.8 g) underwent maximal exercise tests to determine V̇O2 reserve (V̇O2R), being randomly assigned to three groups: moderate-intensity continuous exercise at speed corresponding to 50% V̇O2R (MIC; n=11); high-intensity continuous exercise at 80% V̇O2R (HIC; n=11)...

Texto completo