2007-02

Effect of thermocycling on the tensile and shear bond strengths of three soft liners to a denture base resin

STATEMENT OF PROBLEM: In clinical practice, loss of adhesion between the silicone-based denture liner and the denture base resin is always an undesirable event that might cause loss of material softness, water sorption, bacterial colonization and functional failure of the prosthesis. PURPOSE: This study evaluated the effect of thermocycling on tensile and shear bond strengths of three soft liner materials to a denture base acrylic resin. MATERIAL AND METHODS: Three resilient liners (Mucopren-Soft, Mollosil-Plus and Dentusil) and a heat-polymerized acrylic resin (QC-20) were processed according...