Stationary Phase
Mostrando 1-12 de 2262 artigos, teses e dissertações.
-
1. Per-Aqueous Liquid Chromatography for the Separation of Polar Compounds Preparation and Characterization of Poly(ethylene oxide co dimethylsiloxane) Based Stationary Phase
Poly(ethylene oxide-co-dimethylsiloxane) was thermally immobilized on silica particles-Si(PEO)-to separate small polar compounds with water-rich mobile phases. Poly(ethylene oxide-co-dimethylsiloxane) content on Si(PEO) stationary phase was optimized using a central composite design. Infrared spectroscopy, scanning electron microscopy, and thermogravimetric
Journal of the Brazilian Chemical Society. Publicado em: 2022
-
2. Development and application of a test mixture for untargeted liquid chromatography-mass spectrometry analysis of urine samples
Metabolic profiling of complex biological matrices based on liquid chromatography-mass spectrometry (LC-MS) allows detecting a wide range of metabolites with distinct concentrations and physicochemical properties. Given the complexity of samples and the necessity of a comprehensive approach in untargeted metabolomics, quality control strategies are mandatory
Química Nova. Publicado em: 2022
-
3. HPLC METHOD IMPROVEMENT FOR 4-NONYLPHENOL DETERMINATION IN ANAEROBIC REACTORS: DECREASING SOLVENT CONSUMPTION AND WASTE GENERATION
The aim of this study was to develop a chromatographic method for 4-NP determination in anaerobic batch reactors using low amount of organic solvents and also evaluate 4-NP degradation in the presence of different co-substrates. Chromatographic parameters was improved for stationary phase (C-8 column), mobile phase (acetonitrile/water solution 90:10, v:v), c
Quím. Nova. Publicado em: 2020-09
-
4. CONSTRUÇÃO DE MINI FORNO PARA FUNCIONALIZAÇÃO TÉRMICA DE FASES ESTACIONÁRIAS MONOLÍTICAS
The present work describes a mini oven built to be applied in the preparation of monolithic stationary phase through the thermal polymerization approach. The developed device was successfully tested for functionalization of monolithic stationary phase in the internal surface of the silica capillary column fused with gold nanoparticles.
Quím. Nova. Publicado em: 2020-03
-
5. AVALIAÇÃO DE ADITIVOS DE FASE MÓVEL E TEMPERATURA NA VIDA ÚTIL DE COLUNAS PARA CROMATOGRAFIA LÍQUIDA DE ALTA EFICIÊNCIA
Buffered solutions, additives, and column temperature are widely used in high-performance liquid chromatography to promote adequate retention of compounds and to improve the chromatographic separation. However, these factors can dramatically reduce the column lifetime. In this work, the effect of column temperature, pH and the salt type and concentration in
Quím. Nova. Publicado em: 2020-03
-
6. Microwave Assisted Ultra-Fast Method to Synthesize Carbonate-Phosphates, Na3MCO3PO4 (M = Mn, Fe, Co, Ni) - Relevant Materials Applied in Sodium-Ion Batteries
Although largely used in mobiles and electric vehicles applications, insertion batteries based on Li-ion technology are high-cost devices. These applications require high-performance energy storage systems with high-energy and high-power densities, which are better attained by Li-ion technology. However, stationary applications such as power plants and unint
J. Braz. Chem. Soc.. Publicado em: 2020-01
-
7. Simultaneous determination of anti-diabetic drugs
A novel reverse phase, isocratic HPLC method is described to separate five anti-diabetic drugs i.e., glimepiride, metformin, sitagliptin, rosiglitazone and pioglitazone. Nucleosil C18 analytical column was used as stationary phase, while mobile phase consisted of acetonitrile:phosphate buffer: methanol (40/40/20, v/v) pH 2.0. Effluent was monitored at a flow
Braz. J. Pharm. Sci.. Publicado em: 20/12/2019
-
8. Mecanismos de queda do fluxo em membranas de microfiltração de poliéterimida aplicadas à clarificação de água produzida sintética
RESUMO Membranas de microfiltração de poliéterimida foram preparadas pelo método de inversão de fases para controlar a espessura, porosidade e tamanho de poros dos filmes. 1-metil-2-pirrolidona foi utilizada como solvente e água como não solvente. As propriedades das membranas foram avaliadas por meio de microscopia eletrônica de varredura, microfilt
Matéria (Rio J.). Publicado em: 25/11/2019
-
9. SBSE(EG-Silicone)-UFLC-MS/MS and HPLC-Flu Analysis of Norharman in Passiflora edulis Rinds
Previous studies on Passiflora edulis (sour passion fruit) rinds reported some biological activities and there is a growing interest on rinds flour as a possible functional food, but its alkaloid composition was not detailed investigated. This work reports on for the first time in the literature the identification of norharman in P. edulis rinds, by using st
J. Braz. Chem. Soc.. Publicado em: 24/10/2019
-
10. Synthesis of Hybrid Monolithic Columns Using a Click Chemistry Reaction for Application in Capillary Liquid Chromatography
Hybrid monolithic columns present characteristics of both silica and organic monoliths, such as good mechanical properties, wide pH tolerance, high permeability and stability and little swelling or shrinkage. A common way to prepare this type of material is by using alkoxysilanes and organic monomers via the sol-gel process and click chemistry reactions. In
J. Braz. Chem. Soc.. Publicado em: 24/10/2019
-
11. Chemical Composition and Anti-Inflammatory Activity of the Decoction from Leaves of a Cultivated Specimen of Myracrodruon urundeuva
Myracrodruon urundeuva (Anacardiaceae) is the scientific designation of “aroeira-do-sertão”, a tree well dispersed at the northeastern Brazil. The medicinal use of this plant is widespread throughout the rural population and the inner trunk bark decoction is used to treat cutaneous affections, urinary and respiratory diseases, and gynecological problems
J. Braz. Chem. Soc.. Publicado em: 12/08/2019
-
12. ARTIFACTS IN THE ANALYSIS AND ASSESSMENT OF LOW-COST CONTAINERS FOR SAMPLING AND STORING GREENHOUSE GASES
The objectives of this study were twofold: to assess two chromatographic methods for the analysis of greenhouse gases (GHG) and carbon monoxide, and to propose and evaluate a low-cost and reusable alternative system for their sampling and storage, using 10 different container configurations (flasks and bags). To that end, standard samples containing the gase
Quím. Nova. Publicado em: 2019-01