Resonance Frequency
Mostrando 1-12 de 282 artigos, teses e dissertações.
-
1. A New Miniaturized Low-Profile and Stable Dual-Band FSS with 2.5D Structure for ISM Bands
Abstract Based on 2.5-Dimensional (2.5D) frequency selective surface (FSS) structures, a new miniaturized frequency selective surface structure is proposed in this work to operate as a bandreject filter in the 2.4 GHz (2400 to 2483.5 MHz) and 5 GHz (5150 to 5350 MHz and 5470 to 5725 MHz) ISM (Industrial, Scientific, and Medical) bands. The FSS has the metall
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
2. Frequency Reconfigurable Near-Zero Refractive Index Material for Antenna Gain Enhancement Applications
Abstract In this paper, a planar near-zero refractive index material (NZRIM) consisting of an outer loop with four symmetrical quarter-rings is proposed. The quarter-rings are connected to the outer loop by two symmetrical microstrip lines on the opposite side. The backside of the substrate has mutually central split microstrip lines. By loading adjustable c
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
3. Semi-analytical Equations for Designing Terahertz Graphene Dipole Antennas on Glass Substrate
Abstract Semi-analytical equations are developed for aiding the process of designing terahertz graphene-based rectangular dipole antennas lying on glass substrates. It directly provides the dipole length required for obtaining resonance at a desired frequency since antenna width and graphene chemical potential are known. By using the finite-difference time-d
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
4. Frequency of lipid-poor adrenal adenomas in magnetic resonance imaging examinations of the abdomen
Resumo Objetivo: Estimar a frequência de adenomas pobres em lipídios (APLs) em exames de ressonância magnética (RM). Materiais e Métodos: Investigaram-se, retrospectivamente, as lesões adrenais em exames de RM realizados de janeiro de 2016 a dezembro de 2017. Um total de 2.014 pacientes foi submetido a exames abdominais e, após exclusões, 69 pacien
Radiologia Brasileira. Publicado em: 2022
-
5. YIG Matrix Based Multiband Magneto-Dielectric Cylindrical Resonator Antenna
Abstract A multiband magneto-dielectric resonator antenna with cylindrical geometry is proposed in this paper. The resonator is composed of yttrium iron garnet (YIG) with chemical composition Y3Fe2(FeO4)3. The final structure is built on a low-cost FR4 dielectric substrate. With only one resonator, the antenna is able to resonate in three distinct controlled
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2021-06
-
6. Evaluation of relationships between presence of adhesio interthalamica and cannabis use in first-episode psychosis: a magnetic resonance imaging investigation
ABSTRACT Recent studies suggested that cannabis use influences on the emergence of psychosis by disrupting neurodevelopmental processes that occur during adolescence and early adulthood and which are reflected on brain anatomical changes detectable with MRI. However, no MRI studies have investigated whether intrauterine neurodevelopmental abnormalities also
Arch. Clin. Psychiatry (São Paulo). Publicado em: 2021-04
-
7. Should ethanol be considered a treatment for COVID-19?
Abstract This paper describes the analysis of the effects of a frequency selective surface (FSS) on the characteristics of a microstrip line fed antenna with a bow-tie slot in the ground plane for operation in the frequency range 1 to 10 GHz. The use of the FSS is proposed to miniaturize the antenna structure and increase the number of resonance frequencies
Rev. Assoc. Med. Bras.. Publicado em: 2020-09
-
8. Effects of an FSS Reflector on a Microstrip Line Fed Bow-Tie Slot Antenna
Abstract This paper describes the analysis of the effects of a frequency selective surface (FSS) on the characteristics of a microstrip line fed antenna with a bow-tie slot in the ground plane for operation in the frequency range 1 to 10 GHz. The use of the FSS is proposed to miniaturize the antenna structure and increase the number of resonance frequencies
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-09
-
9. The Role of Magnetic Resonance Imaging of the Temporomandibular Joint to Investigate Tinnitus in Adults with Temporomandibular Joint Disorder: A Comparative Study
Abstract Introduction The prevalence of tinnitus is higher in individuals with temporoman- dibular joint disorder (TMD) than in the general population. Magnetic resonance imaging (MRI) of the temporomandibular joint (TMJ) is the method of choice for investigation, and it has been hypothesized that specific MRI findings might be observed in TMD with comor
Int. Arch. Otorhinolaryngol.. Publicado em: 2020-03
-
10. Sixteenth-Mode Substrate-Integrated-Waveguide (SMSIW) Resonator for Dielectric Characterization of Liquid Mixtures
Abstract In this work, a new concept of planar resonator technique for measurement of liquid mixture permittivity is proposed, designed, and implemented using a Sixteen-Mode Substrate Integrated Waveguide (SMSIW) technology. To design the proposed sensor, the conventional SMSIW resonator is designed with an additional air hole on the open side, and then we a
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-03
-
11. 3.4/4.0 GHz Tunable Resonant Cavity in SIW Technology Using Metal Post and PIN Diode on a Low-Cost Biasing Network for 5G Applications
Abstract This paper presents a dual-band resonant cavity in Substrate Integrated Waveguide (SIW) technology to operate in the range from 3.3 GHz to 4.2 GHz, spectrum considered for the Fifth Generation (5G) network. The cavity was designed to operate at 3.4 GHz and 4.0 GHz. To achieve different states, a jumper and a PIN diode switch are considered as switch
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-03
-
12. MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY (MRCP) VERSUS ENDOSONOGRAPHY-GUIDED FINE NEEDLE ASPIRATION (EUS-FNA) FOR DIAGNOSIS AND FOLLOW-UP OF PANCREATIC INTRADUCTAL PAPILLARY MUCINOUS NEOPLASMS
RESUMO Racional: A neoplasia intraductal mucinosa papilífera (NIMP) está sendo diagnosticada com maior frequência. O método mais utilizado para diagnóstico é a tomografia computadorizada. No entretanto, a colangiopancreatoressonância (CPRM) proporciona melhor caracterização tipo e extensão. A ecoendoscopia com punção por agulha fina (EPAAF), por
ABCD, arq. bras. cir. dig.. Publicado em: 20/12/2019