Reactive Power Support
Mostrando 1-12 de 15 artigos, teses e dissertações.
-
1. Distributed generators performance during short-circuits considering fault ride-through requirements / Desempenho de geradores distribuídos durante curtos-circuitos considerando requisitos de suportabilidade a afundamentos de tensão = : Distributed generators performance during short-circuits considering fault ride-through requirements
The increase of distributed generation penetration in distribution systems not only helps to diversify the electrical matrix but also brings both technical and economic benefits. Yet, it also raises worries related to energy supply reliability. For wind power plants into the medium and high voltage networks there are the grid codes for "Fault Ride-Through" w
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 03/08/2012
-
2. Analysis of flicker level on the integration of fixed speed wind generators using multidiscipline models / Análise dos níveis de flicker na integração de geradores eólicos de velocidade fixa em redes de distribuição de energia elétrica utilizando modelos multidisciplinares
The discussions about the environmental issues and the need for renewable sources of energy, with low environmental impacts, mainly about CO 2 emission, have encouraged the Wind Energy expansion. The support for wind energy in the last decades enabled the improvement of the technology and a representative share in the electrical systems of some countries. Th
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 29/04/2011
-
3. Serviços ancilares através da geração distribuíba : reserva de potência ativa e suporte de reativos / Ancillary services provide by distributed generation : active power reserves and reactive support
In order to set the principles for a future regulatory framework in Brazil which involves the participation of distributed generation (DG) to provide ancillary services; this work presents an analysis developed in three broad areas, technical, economic and regulatory. A specific objective of the project is to make an analysis of the use of the DG for the sup
Publicado em: 2009
-
4. Serviço ancilar de potência reativa de geradores síncronos: aspectos técnicos e regulatórios / Synchronous Generator Reactive Power Service: Technical and Regulatory Aspects
Este trabalho analisa aspectos técnicos e regulatórios dos serviços ancilares de geradores síncronos, no suporte de reativos, e enfatiza que as regras brasileiras, não estimulam investimentos para atender este propósito e isto pode degradar estes recursos. No passado, os sistemas elétricos ao redor do mundo costumavam ser serviços públicos centraliz
Publicado em: 2008
-
5. MÉTODO DE ALOCAÇÃO DE CUSTOS DE SUPORTE DE POTÊNCIA REATIVA BASEADO EM LEIS DE CIRCUITOS / REACTIVE POWER SUPPORT COST ALLOCATION METHOD BASED ON CIRCUIT LAWS
Com a implantação do novo modelo econômico nos sistemas de potência, a justa remuneração das empresas provedoras de serviços ancilares tem se tornado um assunto grande importância. O suporte de potência reativa, por se tratar também de um serviço ancilar, está inserido neste contexto. Desta forma, a factível identificação dos agentes benefici
Publicado em: 2007
-
6. Metodologia para otimizacao da recomposicao de sistemas eletricos baseada na busca tabu seletiva adaptativa / Methodology for optimization service restoration of electrical systems based adaptive selective Tabu search
This dissertation presents a methodology proposed to optimize the restoration of transmission electrical systems, as well as to develop a tool for training and support, in real time, to the system s operators to the System Operation Center - SOC. The proposed methodology, called Adaptive Selective Tabu Search, is based on the Tabu Search technique and some c
Publicado em: 2007
-
7. Perdas aparentes serie como criterio a ser minimizado no fluxo de potencia otimo reativo / Series apparent losses as a criterion to be minimized on reactive optimal power flow
The classic performance indexes, used on reactive power supply and voltage profile analysis, are the sum of active and series reactive power losses that occur on transmission systems, under determined load conditions. The minimization of active or reactive losses, changes significantly the reactive power supply required from the transmission system to suppor
Publicado em: 2006
-
8. Valoração do fornecimento de serviços ancilares a partir de usinas hidroelétricas. / Ancillary services supply pricing from hydroelectric plants.
O presente trabalho propõe o desenvolvimento de uma metodologia de valoração da reserva de potência ativa e do suporte de potência reativa a partir de plantas hidroelétricas. Inicialmente foi apresentado um histórico que descreveu o que foi definido e regulamentado sobre estes serviços em diferentes mercados de energia. Em seguida, com o objetivo de
Publicado em: 2006
-
9. "Projeto é como branco trabalha; as lideranças que se virem para aprender e nos ensinar": experiências dos povos indígenas do alto rio Negro
This dissertation is the outcome of two years of association with the Graduate Program in Social Anthropology of the University of Brasília, at its Masters course. It is a tentative organization of the main ideas, and pratices lived within and outside academia, conscious of the limits this genre of written finite work impose on a rich experience. I examine
Publicado em: 2006
-
10. REMUNERAÇÃO DOS SERVIÇOS ANCILARES DE SUPORTE DE POTÊNCIA REATIVA E RESERVA DE POTÊNCIA QUANDO PROVIDOS POR GERADORES / PRICING THE ANCILLARY SERVICES OF REACTIVE POWER SUPPLY AND GENERATION RESERVE WHEN PROVIDED BY GENERATORS
Este trabalho apresenta metodologias para definir a remuneração dos geradores que provêem serviços ancilares em função do benefício proporcionado ao sistema. São analisados os serviços ancilares de suporte de potência reativa e reserva de potência. Para o serviço ancilar de suporte de potência reativa, o valor do benefício proporcionado pelos g
Publicado em: 2005
-
11. Effects of dimethylsulfoxide, lipoic acid or ternatin pretreatment upon the oxidative stress in young rats subjected to torsion of the spermatic cord / Efeitos do pré-tratamento com dimetilsufóxido, ácido lipóico ou ternatina sobre o estresse oxidativo
The protective role of dimethylsulfoxide (DMSO), lipoic acid (LA) and ternatin (TN), known free radical scavengers and cell membrane protectants were evaluated in an experimental model of testis ischemia/reperfusion. One hundred and twenty young male Wistar rats, mean weight 172.515g, were randomized in five equal groups (GS - Sham, GC Control, GD Dimethylsu
Publicado em: 2005
-
12. ACTUAL REACTIVE POWER CAPABILITY EVALUATION IN AN ELECTRICAL POWER PLANT / AVALIAÇÃO DA CAPACIDADE REAL DE GERAÇÃO DE POTÊNCIA REATIVA EM UMA USINA DE GERAÇÃO DE ENERGIA ELÉTRICA
They show that different generator loads produce greater heating in different parts of generator. A method is described and a software is presented to evaluate the actual reactive power capability curve considering the operating condition.This paper shows that it is possible to enlarge the reactive power capability only by knowing the actual capability limit
Publicado em: 2002