Radiation B
Mostrando 1-12 de 839 artigos, teses e dissertações.
-
1. Quais os cuidados devem ser tomados durante o tratamento odontológico de gestantes portadoras de anemia falciforme?
Gestação e anemia falciforme são duas condições especiais das quais o dentista precisa estar ciente para realizar com segurança o atendimento odontológico.
1. Estudos demonstram que o período mais seguro para tratamento em gestantes é durante o segundo trimestre de gestação
. A maioria dos tratamentos odontológicos pode ser reali
Núcleo de Telessaúde Espírito Santo. Publicado em: 12/06/2023
-
2. The Contribution of Meteorological Parameters and the COVID-19 Partial Lockdown on Air Quality in Rio de Janeiro, Brazil
This study evaluated the pollutant levels (NO2, SO2, CO, and O3), air quality index (AQI) and the influence of meteorological variables and coronavirus disease (COVID-19) pandemic on the air quality in Rio de Janeiro. The data set used comprises periods before (March-April, 2019) and during pandemic (March-April, 2020). According to the AQI results, on most
Journal of the Brazilian Chemical Society. Publicado em: 2023
-
3. Radiation Efficiency of an Electrically Small Dual-band UHF Microstrip Patch Antenna Using Wheeler Cap Method
Abstract Determining the radiation efficiency of an antenna is a difficult task that becomes challenging when it is about electrically small antennas. This work investigates the applicability of the Wheeler cap method to measure the radiation efficiency of a UHF dual-band compact microstrip patch antenna. An overview of Wheeler method is presented. An adapta
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
4. Series Fed Designs of Planar Circular and Hexagonal Microstrip Antenna Arrays for High Gain and Reduced First Side Lobe Level Radiation
Abstract To achieve a high gain and low first side-lobe level, variants of linear and planar series fed circular and hexagonal microstrip antenna arrays using the binomial distribution, are proposed around 3000 MHz frequency band, on thinner Arlon substrate (h ~ 0.027λg). The linear 7 × 1 array of circular patches, yields first side-lobe level of −25 dB
Journal of Microwaves, Optoelectronics and Electromagnetic Applications. Publicado em: 2022
-
5. USE OF BENCHES WITH REFLECTIVE MATERIAL TO FAVOR PRODUCTION OF RUBBER TREE ROOTSTOCK SEEDLINGS
ABSTRACT Success in production of any perennial tree depends on the use of high-quality seedlings. This study aimed to evaluate cultivation benches with reflective material and protected environments for production of rubber tree rootstock seedlings. The experiments were conducted in two types of protected environments: 35% shading aluminized screen and 30%
Eng. Agríc.. Publicado em: 2021-08
-
6. YIG Matrix Based Multiband Magneto-Dielectric Cylindrical Resonator Antenna
Abstract A multiband magneto-dielectric resonator antenna with cylindrical geometry is proposed in this paper. The resonator is composed of yttrium iron garnet (YIG) with chemical composition Y3Fe2(FeO4)3. The final structure is built on a low-cost FR4 dielectric substrate. With only one resonator, the antenna is able to resonate in three distinct controlled
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2021-06
-
7. Non-Ionizing Radiation Analysis in Close Proximity to Antenna Tower: A Case Study in Northeast Brazil
Abstract While the amount of telecommunications services grows rapidly in the whole world, humans get potentially more exposed to Non-Ionizing Radiation (NIR) from a number of different sources. Measurements of NIR levels are relevant in order to compare the results with national and international standards, aiming at the preservation of human health. Thus,
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2021-03
-
8. Omni-Directional Wideband Antenna Array with Solar Cells
Abstract Distributed sensor networks are becoming more and more widespread due to their substantial benefits to our daily lives. These sensors, in most cases, are distributed in nature and even may require mobility. This, in turn, implies omnidirectional collector units to collect the data from various sensors at arbitrary directions. This work summarizes th
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2021-03
-
9. Pelvic floor muscles after prostate radiation therapy: morpho-functional assessment by magnetic resonance imaging, surface electromyography and digital anal palpation
ABSTRACT Aim: To evaluate the radiotherapy (RT) effect in the pelvic floor muscles (PFM) function in men with prostate cancer (PC). Materials and Methods: A cross-sectional study included three groups of patients with PC and RT indication: 1) Pre-RT group: evaluated before the beginning of RT; 2) Acute group: evaluated between six months and one year after
Int. braz j urol.. Publicado em: 2021-02
-
10. Metamaterial-Fractal-Defected Ground Structure Concepts Combining for Highly Miniaturized Triple-Band Antenna Design
Abstract In this paper, a novel method is proposed to increase the gain and radiation efficiency of a compact patch antenna. By employing a combination of three efficient techniques, we have developed a multi-resonance L-DGS antenna with a high gain of 5 dB and an efficiency of 99.6%. Furthermore, a novel compact Double Negative metamaterial unit cell and it
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-12
-
11. A Compact, Wideband, Dual Polarized CPW-Fed Asymmetric Slot Antenna for Wireless Systems
Abstract Wideband, dual sense circularly polarized (CP), asymmetric circular slot fed by coplanar waveguide is proposed and designed. Dual polarizations are obtained by using a horizontal stub to the feed line and embedding the L-shaped strip onto the slotted ground plane. The simulated result of impedance bandwidth shows wideband performance is produced by
J. Microw. Optoelectron. Electromagn. Appl.. Publicado em: 2020-09
-
12. [Elastografia acoustic radiation force impulse (ARFI) da articulação do joelho de beagles saudáveis]
RESUMO O objetivo foi estabelecer os padrões normais para elastografia das principais estruturas da articulação do joelho em cães. O menisco medial, ligamento patelar e cruzado de trinta beagles saudáveis foram avaliados pelo modo B e elastografia ARFI (n=60 articulações). A análise detectou uma correlação positiva da velocidade de cisalhamento (SW
Arq. Bras. Med. Vet. Zootec.. Publicado em: 2020-09