Prosthetic Abutment
Mostrando 1-12 de 26 artigos, teses e dissertações.
-
1. Influence of Abutment Collar Height and Implant Length on Stress Distribution in Single Crowns
Resumo Este estudo avaliou a influência da altura da porção transmucosa do pilar protético com junção cone morse e do comprimento dos implantes no comportamento biomecânico coroas unitárias com diferentes proporção coroa-implante. Seis modelos virtuais (S11, M11, L11, S13, M13 e L13) foram construídos combinando pilares protéticos com transmucoso
Braz. Dent. J.. Publicado em: 03/06/2019
-
2. Prosthetic abutment influences bone biomechanical behavior of immediately loaded implants
Abstract This study aimed to evaluate the influence of the type of prosthetic abutment associated to different implant connection on bone biomechanical behavior of immediately and delayed loaded implants. Computed tomography-based finite element models comprising a mandible with a single molar implant were created with different types of prosthetic abutment
Braz. oral res.. Publicado em: 31/05/2016
-
3. Failure of prosthetic screws on 971 implants
Abstract Aim: To evaluate the presence of failures in prosthetic screws and whether these failures are related to the type of prosthesis, abutment angulation and presence or not of intermediate. Methods: Two-hundred and sixty-seven patients were evaluated at the Federal University of Santa Catarina, totaling 971 external hexagonal implants in place for at
Braz. J. Oral Sci.. Publicado em: 2015-09
-
4. Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla / Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila
The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthe
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 02/08/2012
-
5. Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torque / Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 18/06/2012
-
6. Análise quantitativa do corante azul de Evan extravasado do interior das câmaras internas dos implantes por suas interfaces protéticas nas condições: Hexágono Externo (HE) - Hexágono Interno (HI) - Cone Morse (CM) / Quantitative analysis of Evans blue dye leakage from internal implant chambers through their prosthetic interfaces under the following conditions: External Hexagon (HE) Internal Hexagon (IH) Morse Cone (MC)
Research and studies seek to evaluate the capacity of adaptation and sealing between the implant-intermediate connections of different dental implant systems. It has recently been observed that in implants with screw-retained abutments, various phenomena, such as screw4 loosening and fracture, rotation and fracture of the abutment with bacterial penetration
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 06/09/2011
-
7. Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas : efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implants
The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by s
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 15/04/2011
-
8. Resistance of three implant-abutment interfaces to fatigue testing
The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. Objectives: The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and c
J. Appl. Oral Sci.. Publicado em: 01/07/2011
-
9. A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants
OBJECTIVES: Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in
Journal of Applied Oral Science. Publicado em: 2011-02
-
10. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis
OBJECTIVE: Using strain gauge (SG) analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different mic
Journal of Applied Oral Science. Publicado em: 2010-06
-
11. Desajuste marginal e influencia na pre-carga de parafusos e nas tensões induzidas as fixações de pilares metaloplasticos sobre-fundidos / Marginal misfit and influence in the pre-load and the stress-induced setting of the metaloplastic abutments
Castable UCLA abutments are of wide applicability in dental implants, because they allow the manipulation in the laboratory at low cost and individualization of abutments for each patient. However, they show the worse results of marginal adaptation then the fabricated, although these aggregate costs significantly higher. UCLA premachined abutments for castin
Publicado em: 2010
-
12. Evaluation of abutment and perimplantar region deformation of implant-supported screwed prostheses: an study using strain gauges / Avaliação da deformação do intermediário e região perimplantar de próteses implanto-suportada unitárias parafusada: estudo através da extensometria
The dental implant depends on the supporting bone for its stability and functional longevity. Mechanical behavior and trabecular bone structure affect the interface with the implant. Such knowledge may provide a basis for improvements in the current implant function and design, decreasing bone crest resorption and failure at bone-implant junction. Adequate q
Publicado em: 2010