Nickel Titanium Orthodontic Wires
Mostrando 1-11 de 11 artigos, teses e dissertações.
-
1. Do laypersons perceive aesthetic differences between coated and uncoated orthodontic archwires?
RESUMO Introdução: rotineiramente na terapia ortodôntica fixa, utilizam-se braquetes estéticos combinados com fios metálicos, principalmente devido a algumas desvantagens no uso clínico dos fios estéticos. A percepção estética dos leigos nessa situação precisa ser explorada na literatura. Objetivo: o objetivo deste estudo transversal foi aval
Dental Press J. Orthod.. Publicado em: 2019-02
-
2. Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study
Abstract The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed usi
Braz. oral res.. Publicado em: 21/08/2017
-
3. Evaluation of deflection forces of orthodontic wires with different ligation types
Abstract The aim of this study was to evaluate deflection forces of orthodontic wires of different alloys engaged into conventional brackets using several ligation types. Stainless steel, conventional superelastic nickel-titanium and thermally activated nickel-titanium archwires tied into conventional brackets by a ring-shaped elastomeric ligature (RSEL), a
Braz. oral res.. Publicado em: 03/07/2017
-
4. Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires
Resumo O objetivo foi avaliar a resistência a flexão e os efeitos da deflexão na rugosidade de superfície de fios ortodônticos estéticos. A amostra foi composta por 70 segmentos de fios NiTi calibre 0,014 polegadas: revestidos por politetrafluoretileno (PTFE) (Titanol Cosmetic-TC, Flexy Super Elastic Esthetic-FSE, Aesthetic Nickel Titanium Wire-ANT); r
Braz. Dent. J.. Publicado em: 2017-02
-
5. Mechanical Performance of Nickel-titanium Archwires
The purpose of the present work is to compare the mechanical properties of commercially available NiTi orthodontic archwires lots. Superelastic (SE) and heat-activated (HA) NiTi archwires from two lots of six manufacturers (3M, GAC, Tp, Orthosource, Orthometric and Morelli) were partitioned into eleven groups (n=132) and tested under three-point bending test
Mat. Res.. Publicado em: 03/11/2015
-
6. Degradation of orthodontic wires under simulated cariogenic and erosive conditions
This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing
Braz. oral res.. Publicado em: 04/08/2014
-
7. Relationship between friction force and orthodontic force at the leveling stage using a coated wire
The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Material and Methods: Five esthetic wires (three coated a
J. Appl. Oral Sci.. Publicado em: 2013-12
-
8. Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wires
OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of o
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 03/07/2012
-
9. Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires
OBJECTIVE: This study compared the load-deflection ratios between 0.019 x 0.025-in rectangular orthodontic wires using 5 conventional preformed nickel-titanium (NiTi) and 5 heat-activated NiTi archwires from four different manufacturers (Abzil, Morelli, 3M Unitek and Ormco), totaling 40 archwires. The archwires were placed in typodonts without tooth # 11 and
Dental Press Journal of Orthodontics. Publicado em: 2012-06
-
10. Avaliação das forças, momentos e binding, produzidos por deformação de primeira ordem do fio NiTi .014 superelástico, em braquetes autoligáveis passivos estudo in vitro / Evaluation of force, moment and binding produced by first order deformation on a superelastic .014 Niti wire using passive self-ligated brackets in vitro study
Bracket characteristics and wire stiffness dictate the mechanical effects that nickel titanium wire deformation will cause upon teeth. The main variables associated to bracket characteristics include bracket length (that influence interbracket distance), and coefficient of friction. The purpose of this research was to compare how self ligated brackets such a
Publicado em: 2010
-
11. Relation of forces and deflections during loading and unloading orthodontic nickel-titanium wires / "Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio"
The purpose of this study was to evaluate the behaviour of force as function of loading and unloading orthodontic nickel-titanium wires. Three defferent brands (Forestadent, GAC and Morelli) were tested. Testing temperature were 32, 37 and 42 o C. Loading were up to 1, 2, 3 and 4mm deflection. Specimens consisted of a acrylic base where were fixed metallic c
Publicado em: 2005