Multicommutation
Mostrando 1-12 de 27 artigos, teses e dissertações.
-
1. PROCEDIMENTO AUTOMÁTICO PARA DETERMINAÇÃO ESPECTROFOTOMÉTRICA DE HIDROQUINONA EMPREGANDO MULTICOMUTAÇÃO EM SISTEMA DE ANÁLISE EM FLUXO
This paper describes a procedure based on multicommutation in flow analysis system for photometric determination of hydroquinone in pharmaceutical gel formulations. The procedure involves oxidation of hydroquinone by Fe (III) and subsequent reaction between the generated Fe (II) species with 1,10-phenanthroline, producing a complex detected at 510 nm. Under
Quím. Nova. Publicado em: 2016-06
-
2. Development of a Procedure Based on Chemiluminescence and Multicommutation Approach for the Determination of Folic Acid in Pharmaceuticals
This paper presents an analytical procedure for the determination of folic acid employing commutation flow analysis process and detection by chemiluminescence. The procedure is based on the reaction of hexacyanoferrate(III) with folic acid, followed of luminol oxidizing reaction in alkaline medium, resulting in emission of radiation at 425 nm. After optimiza
J. Braz. Chem. Soc.. Publicado em: 2016-01
-
3. Use of a Digital Image in Flow Analysis: Determination of Nitrite and Nitrate in Natural Waters
A webcam is proposed as the detector in a flow system with multicommutation, and the feasibility of the approach is demonstrated in the determination of nitrate and nitrite in natural waters. The typical transient signal inherent to the flow system was obtained using a digital video and quantified by ImageJ software. The linear dynamics range for nitrite and
J. Braz. Chem. Soc.. Publicado em: 2016-01
-
4. Desenvolvimento de um equipamento portátil e de sistema de análises em fluxo empregando multicomutação. Determinação fotométrica de ferro em águas de rios / Development of a portable equipment and a flow analysis system employing multicommutation. Photometric determination of iron in river waters
Iron is the most abundant element on Earth and plays an important role in biogeochemical cycles. In this work, an automatic analytical procedure was developed for the photometric determination of iron in river waters, employing a LED-based photometer and solenoid mini-pumps for solution handling. The proposed procedure was based on the reaction between iron
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/07/2011
-
5. A compact miniaturized continuous flow system for the determination of urea content in milk.
A multicommutation-based flow system with photometric detection was developed, employing an analytical microsystem constructed with low temperature cofired ceramics (LTCC) technology, a solid-phase reactor containing particles of Canavalia ensiformis DC (urease source) immobilized with glutaraldehyde, and a miniphotometer coupled directly to the microsystem
Analytical & Bioanalytical Chemistry. Publicado em: 2011
-
6. Desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água / Combining multicommuted flow injection analysis and solid phase photometry for the determination of zinc in pharmaceutical preparation and water
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos empregando fotometria em fase sólida para determinação de zinco em produtos farmacêuticos e água. Para implementação do procedimento analítico, todo o sistema foi acoplado a um computador através de uma interface eletrônica. Um software escrit
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 25/08/2010
-
7. Desenvolvimento de procedimento analítico empregando multicomutação em fluxo para determinação fotométrica de cloreto em amostras de coque de petróleo / Development of analytical procedure employing multicommutation for photometric determination of chloride in petroleum coke
In this work was developed an analytical procedure employing multicommutation for the photometric determination of chloride in petroleum coke. The procedure was based on the photometric method described on Stand Method, where the reaction between mercury(II) thyocyanate and chloride causes the displacement of the thyocyanate ions, which reacted with iron(III
Publicado em: 2010
-
8. Automatic photometric titration procedure based on multicommutation and flow-batch approaches employing a photometer based on twin LEDs
Neste trabalho, é descrito um fotômetro de baixo custo baseado em um par de LEDs idênticos, empregando um, como fonte de luz e o outro como fotodetector. O equipamento, incluindo o fotômetro e o módulo de análises, foi projetado para implementar um procedimento de titulação automático empregando o processo de multicomutação por injeção em fluxo
Journal of the Brazilian Chemical Society. Publicado em: 2010
-
9. Study of the feasibility of using solid-phase photometry employing multicommutation, flow cell with 3mm optical path and LED photometer / Estudo da viabilidade da fotometria em fase sólida empregando multicomutação em fluxo, cela de fluxo com caminho óptico de 3mm e fotômetro de LED
No presente trabalho foi estudada a viabilidade da fotometria em fase sólida usando cela de fluxo com caminho óptico de 3 mm e fotômetro de LED, para determinação de cobalto em suplementos vitamínicos digeridos em meio ácido. O método automatizado foi baseado na formação de um composto de cobalto(II) com o reagente cromogênico 1-(2-tiazolilazo)-2-
Publicado em: 2010
-
10. Desenvolvimento de instrumentação e procedimentos automáticos para determinação de arsênio e fluoreto em águas empregando multicomutação em fluxo e detecção fotométrica / Development of instrumentation and automatic procedures for the determination of arsenic and fluoride in waters by using flow multicommutaion and photometric detection
Neste trabalho, é proposto o desenvolvimento de instrumentação e procedimentos analíticos automáticos para a determinação de fluoreto e arsênio em águas empregando o conceito de multicomutação em fluxo e detecção fotométrica. Na determinação de fluoreto, o controle dos dispositivos foi realizado empregando um computador, programado em QuickBa
Publicado em: 2010
-
11. Desenvolvimento de procedimento analítico em fluxo com multicomutação para a determinação espectofotométrica de ácido úrico em urina / Development of a multicommuted flow-based analytical procedure for the spectrophotometric determination of uric acid in urine
Mechanization of analytical procedures in clinical analysis brings advantages such as minimization of systematic errors and analysis time. Multicommuted flow systems attain the requirements to mechanization of analytical procedures in a versatile and robust way, minimizing reagent consumption and waste generation, due to the low solution volumes handled by e
Publicado em: 2009
-
12. Desenvolvimento de procedimentos analíticos limpos e com alta sensibilidade para a determinação de espécies de interesse ambiental / Development of clean analytical procedures with high sensitivity for determination of species of environmental interest
Clean analytical procedures with high sensitivity for the determination of species of environmental interest (carbaryl, sulphate and chlorine) were developed. Flow systems with solenoid micropumps were coupled to long optical pathlength spectrophotometry or cloud point extraction procedures, aiming the concentration of species for determination without emplo
Publicado em: 2009