Modulation Transfer Function
Mostrando 13-24 de 63 artigos, teses e dissertações.
-
13. Efeito da inibição da fosfodiesterase-5 sobre as propriedades de transdução dinâmica do nervo vago cardíaco em ratos espontaneamente hipertensos.
Recent data have reported that sildenafil citrate, an inhibitor of phosphodiesterase-5 (PDE-5), widely used in the treatment of erectile dysfunction, causes vasodilation and reflex sympathetic activation, which may enhance cardiovascular risk. However, the effects of sildenafil citrate on cardiac vagal parasympathetic control, in the arterial hypertension co
Publicado em: 2006
-
14. Estimação da resolução espacial da câmera CCD dos satélites CBERS 1 e 2 / Spatial resolution estimation of CBERS CCD camera
The first China-Brazil Earth Resources Satellite (CBERS-1) was launched in 1999 and was substituted on 2003 by CBERS-2. CBERS- 1 and CBERS-2 have the same specifications and carry three sensors: a Wide Field Imager (WFI), a High Resolution CCD Camera (CCD) and an Infrared Multispectral Scanner (IRMSS). Due to the limitations of the sensor components (diffrac
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 21/03/2005
-
15. Thermal neutron computed tomography at the Argonauta Reactor
Since 1985 the Argonauta Reactor at the Instituto de Engenharia Nuclear - IEN/CNEN has been used as a source of thermal neutrons to acquire transmission-generated radiographic images. From that time until the end of the last century, some Universities and Research Institutions have as well used the irradiation facilities of this reactor for that purpose and
Brazilian Journal of Physics. Publicado em: 2005-09
-
16. Development of a CCD-based image acquiring system for neutrons at the Argonauta Reactor
A thermal neutron image acquiring system is being developed at the Instituto de Engenharia Nuclear-IEN (CNEN). This system would be capable to perform non-destructive assays after 2D images acquired on a real or quasi real time basis as well as 3D tomographic images reconstructed from the two-dimensional ones. The source-detector set is constituted by the Ar
Brazilian Journal of Physics. Publicado em: 2005-09
-
17. Investigação de qualidade para comparação de sistemas de imagem em radiologia odontológica / Quality investigation in order to compare odontologic radiographic image systems
O presente trabalho de pesquisa trata da investigação de parâmetros de qualidade aplicados a sistemas de imagem em radiologia odontológica. Para isso, foram levantados parâmetros propostos pela Portaria nº 453 de 1998 da Secretaria de Vigilância Sanitária do Ministério da Saúde em aparelhos de raios X odontológicos e determinadas funções de tran
Publicado em: 2005
-
18. Improvement of a gaseous position sensitive detector for use in thermal neutron tomographic systems
The utilization of a position sensitive detector in tomographic systems is an attractive possibility because it is capable of furnishing the position where the ionizing event occurs. This feature can reduce significantly the image acquiring time, since a sample translation is no longer required. In this work the performance of a gaseous position sensitive de
Brazilian Journal of Physics. Publicado em: 2004-09
-
19. Real-time neutron radiography at the IEA-R1m nuclear research reactor
A LIXI(Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1m nuclear research reac
Brazilian Journal of Physics. Publicado em: 2003-06
-
20. Restauração de imagens do satélite Landsat-7. / Restoration of LANDSAT-7 satellite images.
The techniques of image restoration are oriented for the modeling of the degradation and recovery of the original signal that was degraded during the process of image formation. In Remote Sensing, sensor?s nominal spatial resolution, that defines the precision with which details of objects of interest in the image are perceivable, is one of the most importa
Publicado em: 2003
-
21. Restauração de imagens do satélite Landsat-7. / Restoration of LANDSAT-7 satellite images.
As técnicas de restauração de imagens são orientadas para a modelagem da degradação e recuperação do sinal original que foi degradado durante o processo de formação de imagens. Em Sensoriamento Remoto, a resolução espacial nominal do sensor, que define a precisão com que os detalhes dos objetos de interesse na imagem são perceptíveis, é uma d
Publicado em: 2003
-
22. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
A faixa espectral do infravermelho termal para sensores aerotransportados ainda é pouco explorada no País. O Instituto de Estudos Avançados (IEAv) do Centro Técnico Aeroespacial (CTA) desenvolveu o Sistema Imageador Infravermelho Termal (SISIMI), um sensor-protótipo termal aerotransportado que opera na faixa de 8 a 12,5 µm e com imageamento por varredu
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 09/10/2002
-
23. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
The thermal infrared spectral bands in airborne sensors are still little explored in Brazil. The Institute of Advanced Studies (IEAv) at the Aerospace Technical Center (CTA) developed the Thermal Infrared Imaging System (SISIMI), an aerial surveillance prototype sensor operating in the 8 to 12.5 um band with a rotating imaging scanner of 720 lines/s. The obj
Publicado em: 2002
-
24. Caracterização de um sistema imageador infravermelho termal através de suas resoluções espacial e radiométrica / Characterization of a thermal infrared line scanner trough its spatial and radiometric resolutions
A faixa espectral do infravermelho termal para sensores aerotransportados ainda é pouco explorada no País. O Instituto de Estudos Avançados (IEAv) do Centro Técnico Aeroespacial (CTA) desenvolveu o Sistema Imageador Infravermelho Termal (SISIMI), um sensor-protótipo termal aerotransportado que opera na faixa de 8 a 12,5 µm e com imageamento por varredu
Publicado em: 2002