Magnetoimpedance
Mostrando 1-12 de 18 artigos, teses e dissertações.
-
1. Domain Transformation and MI of Melt-extracted Co68.15Fe4.35Si12.25B13.25Nb1Cu1 Microwires by Cryogenic Joule Annealing
Giant magneto-impedance (GMI) effect and domain transformation for melt-extracted Co68.15Fe4.35Si12.25B13.25Nb1Cu1 amorphous wires have been induced by a cryogenic Joule annealing (CJA) treatment with different DC current amplitude (0~350 mA) for 240s. Experimental results indicate that the maximum GMI ratio ([ΔΖ∕Ζ0]max) achieves to 188.1% with exciting
Mat. Res.. Publicado em: 17/11/2015
-
2. Efeito do tratamento térmico na relaxação magnética de microfios amorfos de CoFeSiB recobertos por vidro / Effect joule-heated in the magnetic relaxation amorphous glass-covered microwires
Magnetoimpedância tem provado ser uma excelente ferramenta para estudar a dinâmica de magnetização e a largura de linha da ressonância ferromagnética (FMR) fornece uma maneira conveniente para medir parâmetros de amortecimento em materiais magnéticos. A largura de linha FMR depende do amortecimento magnético intrínseco e adicionais inomogeneidades
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 27/02/2012
-
3. Análise por meio da técnica FORC, do efeito da histerese a alta freqüência no fenômeno da GMI / Analysis of the hysteretic effect on the high frequency GMI phenomenon by means of FORC technique
Este trabalho visa estudar o comportamento histerético, observado a baixos campos magnéticos, do fenômeno da magnetoimpedância gigante (GMI) em fitas amorfas a base de CoFeSiB com anisotropia magnética transversal. O fenômeno da GMI consiste na variação da impedância elétrica (aproximadamente do 100%) de uma amostra magnética mole quando submetida
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 15/12/2011
-
4. Caracterização de materiais amorfos, através de medidas de GMI e GMI-FORC / Characterization of amorphous materials by GMI and GMI-FORC measurement
No nosso trabalho utilizamos o fenômeno da magnetoimpedância gigante (GMI) como uma ferramenta de pesquisa na caracterização de ferromagnetos amorfos. Estes materiais são muito moles do ponto de vista magnético, o que pode servir para diversas aplicações, tais como na construção de sensores e de dispositivos de alta frequencia. Na primeira parte da
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 28/11/2011
-
5. DEVELOPMENT OF A TRANSDUCER BASED ON THE PHASE OF THE GIANT MAGNETOIMPEDANCE FOR THE MEASUREMENT OF BIOMAGNETIC FIELDS / DESENVOLVIMENTO DE TRANSDUTOR BASEADO NA FASE DA MAGNETOIMPEDÂNCIA GIGANTE PARA MEDIÇÃO DE CAMPOS BIOMAGNÉTICOS
Esta dissertação tem por objetivo o desenvolvimento de um transdutor magnético baseado no efeito da Magnetoimpedância Gigante (GMI ¿ Giant Magnetoimpedance), destinado à medição de campos biomagnéticos. A motivação deste trabalho advém da inexistência de um sistema de baixo custo capaz de medir satisfatoriamente campos biomagnéticos, operando �
Publicado em: 2010
-
6. MAGNETOIMPEDÂNCIA E DINÂMICA DA MAGNETIZAÇÃO EM NANOESTRUTURAS FERROMAGNETO / Cu (Ag) / FERROMAGNETO
In this work the static and dynamic magnetic properties are investigated in FM/i/Cu(Ag)/i/FM tri-layer structured samples where FM is the ferromagnetic multilayer and i is the SiO2 isolating layer. All samples have been deposited by magnetron sputtering on a glass substrate with a 50 Å Ta buffer layer. The models proposed by L. Spinu for the calculus of the
Publicado em: 2007
-
7. MAGNETOIMPEDÂNCIA COMO FERRAMENTA PARA A CARACTERIZAÇÃO MAGNÉTICA DE MICROFIOS AMORFOS / MAGNETOIMPEDANCE AS A TOOL TO INVESTIGATE THE MAGNETIC PROPERTIES OF MICROWIRES
The possibility of exploring the magnetic properties of amorphous microwires in technological applications has attracted the attention of the scientific community in the last years. Beyond, the magnetoimpedance effect has been established as a powerful tool to study these properties. In this work we show a study of the magnetic properties of Joule heated gla
Publicado em: 2006
-
8. MAGNETOIMPEDANCE IN MULTILAYERS OF Ni81Fe19/Cu WITH THE CHAIN OF PERPENDICULAR SOUNDING LEAD TO THE PLAN OF FILM / MAGNETOIMPEDÂNCIA EM MULTICAMADAS DE Ni81Fe19/Cu COM A CORRENTE DE SONDA PERPENDICULAR AO PLANO DO FILME
Neste trabalho foi estudado o comportamento da magnetoimpedância (MI) em amostras ferromagnéticas (Ni81Fe19) estruturadas em camadas intercaladas com metal normal (Cu) produzidas por magnetron sputtering com a corrente de sonda sendo aplicada perpendicularmente ao plano do filme. A faixa de freqüência usada neste trabalho foi de 100kHz a 1.8GHz num anali
Publicado em: 2006
-
9. DESENVOLVIMENTO DE UM TRANSDUTOR DE PRESSÃO DE ALTA SENSIBILIDADE, BASEADO NO FENÔMENO DE MAGNETOIMPEDÂNCIA GIGANTE, PARA APLICAÇÃO BIOMÉDICA / DEVELOPMENT OF A HIGH SENSITIVITY PRESSURE TRANSDUCER, BASED ON THE PHENOMENON OF GIANT MAGNETOIMPEDANCE EFFECT, FOR BIOMEDICAL APPLICATION
A presente dissertação apresenta o desenvolvimento de um transdutor de pressão de alta sensibilidade, desenvolvido para aplicações biomédicas. O transdutor é baseado em um sensor de magnetoimpedância gigante (MIG), anteriormente desenvolvido, pelo Laboratório de Biometrologia da PUC-Rio. O conhecimento a cerca das principais características do fen�
Publicado em: 2006
-
10. Magnetoimpedance and dynamics of the magnetization in multilayers of Ni81Fe19/Ag and Ni81Fe19/Cu / Magnetoimpedância e dinâmica da magnetização em multicamadas de Ni81Fe19/Ag e Ni81Fe19/Cu
Nesse trabalho foram estudados o efeito magnetoimpedância (MI) e a dinâmica da magnetização em multicamadas de Ni81Fe19/Ag e Ni81Fe19/Cu. As amostras foram produzidas usando a técnica de magnetron sputtering no Laboratório de Magnetismo e Materiais Magnéticos da UFSM com as espessuras de 100 e 200Å para as camadas de Py=Ni81Fe19 e com as espessuras d
Publicado em: 2006
-
11. DEVELOPMENT AND CHARACTERIZATION OF A FIELD MAGNETIC TRANSDUCER BASED ON GIANT MAGNETOIMPEDANCE EFFECT / DESENVOLVIMENTO E CARACTERIZAÇÃO DE UM TRANSDUTOR MAGNÉTICO BASEADO NO EFEITO DA MAGNETOIMPEDÂNCIA GIGANTE
In this dissertation, it is proposed the design of a magnetic field to voltage transducer based on the Giant Magnetoimpedance phenomenon (GMI), characterized by an innovative geometric configuration. In order to attain the best near-field sensibility and far-field immunity, the transducer`s sensitive element and electronic circuit were planned and implemente
Publicado em: 2005
-
12. Linear and non-linear giant magnetoimpedance in amorphous alloys / Magnetoimpedancia gigante linear e não-linear em ligas amorfas
Não informado
Publicado em: 2005