1. Electromechanical Impedance - Based Structural Health Monitoring Instrumentation System Applied to Aircraft Structures and Employing a Multiplexed Sensor Array
ABSTRACT: The electromechanical impedance method has been seen as a promising tool for structural health monitoring regarding different types of structures and purposes. Most importantly, this method can be used in real-time applications. Frequently, massive, high-cost, single-channel impedance analyzers are used to process the time domain data, aiming at ob
J. Aerosp. Technol. Manag.. Publicado em: 2015-09
-
2. Desenvolvimento de ferramenta de comparação de técnicas de processamento de sinais para determinar fadiga muscular por meio do sinal emg / Toolkit development for signals processing technics comparison to detect muscular fadigue by EMG signal
This study aimed to development of a computational tool for electromyographic signal (EMG) analysis by signal processing techniques to determine muscular fatigue. With Ethics Committee of Federal University of Goiás approve were recorded from the dominant biceps brachii of 10 volunteers, that did not ever had muscular disease. The protocol consisted on get
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 09/07/2012
-
3. Correlação entre as espessuras da mácula e da camada de fibras nervosas da retina, medidas pelas tomografias de coerência óptica de dominio Fourier e de domínio do tempo, e a perimetria automatizada na atrofia em banda do nervo óptico / Correlation between macular and retinal nerve fiber layer Fourier domain and time domain optical coherence tomography measurements and visual field loss in band atrophy of the optic nerve
PURPOSE: To investigate the relationship between fourier-domain optical coherence tomography (FD - OCT) measured macular and retinal nerve fiber layer thickness (RNFL) and visual field sensitivity loss on standard automated perimetry in eyes with permanent temporal hemianopia from chiasmal compression and compare the ability of FD - OCT and time-domain optic
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 18/04/2011
-
4. Desenvolvimento de um sistema de imageamento usando a tomografia por coerÃncia Ãptica no domÃnio temporal e de Fourier
In this dissertation, we describe the basic theory and details of the implementation of three experimental optical coherence tomography systems, two in the time domain and one in the spectral (Fourier) domain. Optical coherence tomography (OCT) is a non invasive optical imaging method, capable of producing cross-sectional images of materials and biological t
Publicado em: 2006
-
5. TÃcnicas de Interferometria Ãptica aplicada à medicina, odontologia e comunicaÃÃes Ãpticas
In the work described in this thesis, we used two different interferometric techniques, the coherent optical frequency domain reflectometry (COFDR), and the optical coherence tomography (OCT). Both techniques are based on the Michelson interferometer. They were applied to optical communications and to medical and dentistry imaging. We will give a general des
Publicado em: 2006
-
6. Leak detection pipes by frequency response method and reflections high frequency pulses / Detecção de fugas em tubulações atraves do metodo de resposta em frequencia e reflexões de pulsos de alta frequencia
Nos sistemas de transporte de fluido líquido, têm-se a preocupação em combater às fugas ou vazamentos. Dessa fonna, este trabalho tem como objetivo aperfeiçoar o método de detecção de fugas em tubulações pelo método de resposta nos domínios fteqüência e tempo, utilizando como ferramentas matemáticas o Método da Matriz Transferência / Respos
Publicado em: 2005
-
7. Observation of force-detected nuclear magnetic resonance in a homogeneous field
We report the experimental realization of BOOMERANG (better observation of magnetization, enhanced resolution, and no gradient), a sensitive and general method of magnetic resonance. The prototype millimeter-scale NMR spectrometer shows signal and noise levels in agreement with the design principles. We present 1H and 19F NMR in both solid and liquid samples