Detectors
Mostrando 13-24 de 268 artigos, teses e dissertações.
-
13. Influences of the signal border extension in the discrete wavelet transform in EEG spike detection
Abstract Introduction The discrete wavelet transform is used in many studies as signal preprocessor for EEG spike detection. An inherent process of this mathematical tool is the recursive wavelet convolution over the signal that is decomposed into detail and approximation coefficients. To perform these convolutions, firstly it is necessary to extend signal
Res. Biomed. Eng.. Publicado em: 12/09/2016
-
14. Gas-Phase Polycyclic Aromatic Hydrocarbons in the Parking Lot Impacted by Light-Duty Vehicles Burning Gasoline and Ethanol Blends
In order to study the emission of vapor-phase polycyclic aromatic hydrocarbons (PAHs) by light-duty vehicles burning gasoline and ethanol blends, air samplings were performed at a parking lot in Londrina, PR, Brazil. The samples were obtained during the summer and winter 2012. The semi-volatile PAHs were collected using a cartridge packed with XAD-2 resin, e
J. Braz. Chem. Soc.. Publicado em: 2016-09
-
15. Determination of Phenolic Acids and Quercetin in Brazilian Red Wines from Vale do São Francisco Region Using Liquid-Liquid Ultrasound-Assisted Extraction and HPLC-DAD-MS
This work describes a method for the determination of gallic, caffeic and p-coumaric acids, as well as quercetin, in Brazilian red wines by employing reverse phase high performance liquid chromatography (RP HPLC) coupled to diode array and mass detectors. The method was performed using a sample volume of 10 µL. The limits of detections were 0.36, 0.27, 0.33
J. Braz. Chem. Soc.. Publicado em: 2016-06
-
16. Evaluation of radiation protection conditions in intraoral radiology
Abstract Introduction: The dental radiology represents about 20% of human exposure to radiation in radio diagnostic. Although the doses practiced in intraoral dentistry are considered low, they should not be ignored due to the volume of the performed procedures. This study presents the radiation protection conditions for intraoral radiology in Curitiba - PR
Res. Biomed. Eng.. Publicado em: 17/05/2016
-
17. Study and characterization of indium oxynitride photoconductors
Multifunctional materials are a new class of thin films and coatings. These materials show interesting characteristics for application in many scientific areas, in special electronic and photonic technologies. These characteristics include sensitivity for thermal, light, mechanical, chemical and other influences, high resistivity, high electrical isolation a
Mat. Res.. Publicado em: 03/12/2013
-
18. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs
The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] col
Braz J Med Biol Res. Publicado em: 06/11/2013
-
19. Sistema para medida simultânea de temperatura e deformação com redes de Bragg em 800 nm / Simultaneous measurement of temperature and strain using fiber Bragg gratings written at 800 nm
In recent years, fiber Bragg gratings (FBGs) have been frequently used as strain and temperature sensors. Several studies have tackled the problem of distinguishing between these two physical parameters using a dual-wavelength sensor. Although these sensors have shown good results, they have a few drawbacks, one of them being the need for two light sources w
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 01/11/2012
-
20. CARACTERIZAÇÃO DE DETECTORES DE RADIAÇÃO DE ESPODUMÊNIO. / CHARACTERIZATION OF RADIATION DETECTORS SPODUMENE.
Dosímetros são muito empregados na monitoração de doses de radiação ionizante, sobretudo na dosimetria clínica e ambiental, fazendo-se o uso de técnicas como termoluminescência (TL), emissão exoleletrônica termicamente estimulada (TSEE) e luminescência opticamente estimulada (LOE). Diversas pesquisas têm sido feitas buscando desenvolver materiai
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 02/10/2012
-
21. Estudo sobre a identificação de hádrons em câmaras de fotoemulsão / Study about hadron identification in emulsion chambers
This work introduces the importance of photoemulsion chambers that remain in use after decades and still offer many advantages for elementary particle physics. We cite OPERA (Oscillation Project with Emulsion-tRacking Apparatus) detector that is the greatest lead photoemulsion chamber detector ever constructed as an example of its application nowadays (nine
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 16/04/2012
-
22. Desenvolvimento de um simulador para espectrometria por fluorescência de raios X usando computação distribuída / Development of a X-ray fluorescence spectrometry simulator using distributed computing
Radiation Physics is a branch of Physics that is present in various studying areas and relates to the concept of spectrometry. Among the numerous existing spectrometry techniques, there is the X-ray fluorescence spectrometry. It also has a range of variations which can emphasize a particular subset of techniques. The production of X-ray fluorescence enables
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 30/03/2012
-
23. CARACTERIZAÇÃO DE DISPOSITIVOS ELETRÔNICOS PARA DOSIMETRIA EM TOMOGRAFIA COMPUTADORIZADA. / CHARACTERIZATION OF ELECTRONIC DEVICES FOR DOSIMETRY IN COMPUTED TOMOGRAPHY.
Computed tomography (CT) is an examination of high diagnostic capability that delivers high doses of radiation compared with other diagnostic radiological examinations. The current CT dosimetry is mainly made by using a 100 mm long ionization chamber. However, it was verified that this extension, which is intended to collect all scattered radiation of the si
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 12/03/2012
-
24. O detector de ondas gravitacionais Mario Schenberg: uma antena eférica criogênica com transdutores paramétricos de cavidade fechada. / The Mario Schenberg gravitational wave detector: a spherical cryogenic antenna with parametric transducers of closed cavity
A existência de ondas gravitacionais foi confirmada indiretamente pela observação astronômica de pulsares binários. Detectores de ondas gravitacionais tem sido desenvolvidos desde o trabalho pioneiro de Weber nos anos 60. Esforços estão sendo realizados no sentido de aumentar a sensibilidade dos detectores e realizar uma detecção direta, que ainda n
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 12/03/2012