Biosensor
Mostrando 37-48 de 235 artigos, teses e dissertações.
-
37. Influência dos polieletrólitos na resposta eletroquímica de filmes automontados contendo nanotubos de carbono para aplicação em nanomedicina / Influence the polyelectrolytes on the electrochemical response of layer-by-layer films containing carbon nanotubes for applications in nanomedicine
Carbon Nanotubes (CNTs) are cylindrical carbon nanostructures exhibiting excellent electrical, thermal, optical and mechanical properties. The immobilization of CNTs in nanostructured thin films in conjunction with polymers using the Layer-by-Layer (LbL) technique provides a new alternative for development of nanocomposites to be used as sensors and biosenso
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/06/2011
-
38. Synthesis, characterization and application of poly(3- hydroxyphenylacetic acid) in the development of a biosensor for detection of cardiac marker / Síntese, caracterização e aplicação do poli (ácido 3-Hidroxifenilacético) no desenvolvimento de biossensor para detecção de marcador cardíaco
Neste trabalho foram realizados estudos de caracterização de um novo material, o poli(ácido 3-hidroxifenilacético) e sua aplicação para construção de um imunossensor amperométrico para detecção do Infarto Agudo do Miocárdio (IAM). Inicialmente, foi realizada a eletropolimerização do ácido 3-hidroxifenilacético em três pHs diferentes (0,0; 6,
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 25/02/2011
-
39. A Biosensor Using Poly(4-Aminophenol)/acetylcholinesterase modified graphite electrode for the detection of dichlorvos
The properties of poly(4-aminophenol) modified graphite electrode as material for the immobilization of acetylcholinesterase were investigated by the Cyclic Voltammetry, Electrochemical Impedance Spectroscopy and Atomic Force Microscopy. The polymer was deposited on graphite electrode surface by the oxidation of 4-aminophenol and then acetylcholinesterase wa
Brazilian Archives of Biology and Technology. Publicado em: 2011-12
-
40. Hemoglobina extracelular gigante de Glossoscolex paulistus: um extraordinário sistema supramolecular hemoproteico
Giant extracellular hemoglobins are considered the summit of complexity in systems that carry oxygen, constituting an extraordinary model system to the study of hemoproteins. This class includes the hemoglobin of the annelid Glossoscolex paulistus that presents high cooperativity, great oligomeric and redox stabilities and ability of oligomeric reassociation
Química Nova. Publicado em: 2011
-
41. Biosensors of laccase based on hydrophobic ionic liquids derived from imidazolium cation
Biossensores contendo lacase (Aspergillus oryzae) e líquidos iônicos derivados do cátion 1-butil-3-metilimidazol (BMI) associados com os ânions hexafluorfosfato (BMI•PF6) ou bis(trifluormetilsulfonil)imida (BMI•Tf2N) foram construídos para determinação de adrenalina. O biossensor baseado no BMI•Tf2N foi selecionado por apresentar maior resposta
Publicado em: 2011
-
42. Biossensores eletroquímicos fabricados a partir da imobilização da urease em filmes de polipirrol / Electrochemical biosensors fabricated by the immobilization of urease in polypyrrole films
A urease (Canavalia ensiformis DC.) foi fisicamente imobilizada em matrizes de polipirrol (PPI) com o objetivo de se detectar uréia em amostras padrão. A eletropolimerização do pirrol foi realizada por voltametria cíclica em uma faixa de potencial de -1,0 a 1,0 V vs. ECS em um meio aquoso contendo 0,2 mol/L de LICLO IND.4e 0,1 mol/L de pirrol. Este proc
Publicado em: 2011
-
43. DESENVOLVIMENTO DE METODOLOGIAS ELETROQUÍMICAS PARA MONITORAMENTO AMBIENTAL DA RIFAMPICINA E SUA ELETRODEGRADAÇÃO PELA GERAÇÃO DE AGENTES OXIDANTES IN SITU. / DEVELOPMENT OF METHODOLOGIES FOR ELECTROCHEMICAL ENVIRONMENTAL MONITORING OF YOUR E RIFAMPICIN ELETRODEGRADAÇÃO GENERATION BY OXIDIZING AGENTS IN SITU.
The drugs are considered pollutant emergent, a time that its presence in aquatic environments is each bigger time. This research has as objective to develop electrochemical methodologies that allow to monitor and to degrade the rifampicin in water of public supplying. In the stage of monitor a voltammetric method was developed using a biosensor of chitosan f
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 25/10/2010
-
44. Desenvolvimento de dispositivos eletroquímicos descartáveis para análises rápidas / Development of disposable electrochemical devices for rapid analysis
This paper presents the efforts to the construction and characterization of electrochemical transducers on polyester and paper, and also demonstrates the use of these disposable electrochemical cells in the development of a biosensor for rapid analysis of salicylate in blood as well as the creation of a separation device associated electrochemical detection
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/08/2010
-
45. Low potential stable glucose detection at dendrimers modified polyaniline nanotubes
The utilization of nanostructured materials for development of biosensors is a growing field in medical diagnostics. In this work a glucose biosensor based on bioactive polyglycerol (PGLD) and chitosan dendrimers (CHD) was developed. PGLD and CHD were bioconjugated with the enzyme glucose oxidase (GOx) to obtain dendrimers with glucose sensing properties. Po
Materials Research. Publicado em: 2010-03
-
46. Desenvolvimento de metodologia para funcionalizar superfícies de ouro com biomoléculas. Construção de biosensor para detecção de citocromo c. / Development of methodology to functionalize gold surfaces with biomolecules. Construction of biosensor for detection of cytochrome c
Neste trabalho estão apresentadas novas estratégias para funcionalizar superfícies de ouro baseadas na sustentação de bicamadas lipídicas em superfícies de sensores de imagem por Ressonância de Plasmons de Superfície (SPRi) e a construção de um biosensor para detecção de citocromo c. SPRi é uma técnica ótica de gravimetria em tempo real. Por
Publicado em: 2010
-
47. Desenvolvimento de nanoestruturas de ZnO para aplicação em um biosensor de glicose
O objetivo deste trabalho é desenvolver e caracterizar filmes de ZnO nanoestruturados com o propósito de se construir um biosensor de glicose. Os filmes foram preparados sobre substratos diferentes (vidro, silício e aço inox), utilizando o método hidrotérmico. A síntese hidrotérmica é um processo relativamente simples e de baixo custo, que uma vez o
Publicado em: 2010
-
48. Identificação de microcistina LR ao nível molecular empregando microscopia de força atômica
Microcystins are non-ribosomal peptides that must be detected for its health concern. Here, microcystin LR and its specific antibody were respectively tethered to the substrate and to the tip of an atomic force microscope, after surface functionalization using 3-aminopropyltriethoxysilane and glutaraldehyde. Functionalization was confirmed comparing topograp
Química Nova. Publicado em: 2010