Transcatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.
AUTOR(ES)
Reidy, J F
RESUMO
A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a further operation a silicone filled balloon was detached in the Blalock-Taussig shunt and this successfully closed the fistula.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=481378Documentos Relacionados
- Balloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.
- Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.
- Balloon dilatation of stenosed Blalock-Taussig shunts.
- False aneurysm following modified Blalock-Taussig shunt.