Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral
AUTOR(ES)
Cleland, J.
RESUMO
The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfactory and not without hazards.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=469989Documentos Relacionados
- Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses
- Results after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).
- Acute dysfunction of Starr-Edwards mitral prostheses
- THROMBO-EMBOLIC PRIMARY PULMONARY ARTERIOSCLEROSIS