Scanning Electrochemical Microscopy (SECM) Study of the Electrochemical Behavior of Anodized AZ31B Magnesium Alloy in Simulated Body Fluid
AUTOR(ES)
Oliveira, Leandro Antonio de
FONTE
Mat. Res.
DATA DE PUBLICAÇÃO
28/10/2019
RESUMO
In this work, scanning electrochemical microscopy (SECM) was employed to study the corrosion behavior of anodized AZ31B magnesium alloy exposed to simulated body fluid. SECM measurements were carried out in surface generation/tip collection mode. The hydrogen evolution flux caused during corrosion of the magnesium alloy was oxidized at the ultra-microelectrode (UME). Thus, this experimental procedure allowed evaluating the effect of the anodic protection in this alloy from the SECM analysis of Z- approximation curves, cyclic voltammograms and topographic maps. The results evidence differences in the local electrochemical response of magnesium alloy in the anodized and pristine conditions. The main sites of H2 evolution were verified in the magnesium alloy without anodizing at short exposure times.
Documentos Relacionados
- Study of behavior alloy Ti and 316L in to simulated body fluid by electrochemical techniques
- Effect of Scroll Pin Profile and Tool Rotational Speed on Mechanical Properties of Submerged Friction Stir Processed AZ31B Magnesium Alloy
- The Electrochemical Behavior of the NiTi Alloy in Different Simulated Body Fluids
- Compressive deformation behavior modeling of AZ31 magnesium alloy at elevated temperature considering the strain effect
- Estudo do processo de soldagem por fricção por ponto da liga de magnésio AZ31