Rapid detection of significant bacteriuria by use of an automated Limulus amoebocyte lysate assay.
AUTOR(ES)
Jorgensen, J H
RESUMO
Previous studies have demonstrated that significant gram-negative bacteriuria can be detected by using the Limulus amoebocyte lysate test. A series of 580 urine specimens were tested in parallel with the automated MS-2 (Abbott Laboratories) assay and with quantitative urine bacterial cultures. The overall ability of the MS-2 Limulus amoebocyte lysate test to correctly classify urine specimens as containing either greater than or equal to 10(5) organisms or less than 10(5) organisms per ml during a 20-min test period was 92.6%.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=272421Documentos Relacionados
- Rapid detection of Gram-negative bacteriuria by Limulus amoebocyte lysate assay.
- Chromogenic Limulus amoebocyte lysate assay for rapid detection of gram-negative bacteriuria.
- Rapid detection of gram-negative bacterial peritonitis by the Limulus amoebocyte lysate assay.
- Detection of endotoxin in the plasma of patients with gram-negative bacterial sepsis by the Limulus amoebocyte lysate assay.
- Rapid Detection of Gram-Negative Bacteriuria by Use of the Limulus Endotoxin Assay