Precisão e acurácia de medidas lineares da mandíbula em imagens 3D obtidas por meio da tomografia computadorizada de feixe cônico / Accuracy and reliability of mandibular linear measurements on 3D CBCT images with different voxel sizes
AUTOR(ES)
Thais Maria Freire Fernandes
FONTE
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia
DATA DE PUBLICAÇÃO
29/09/2011
RESUMO
Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different voxel sizes. Methods: Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®, independently, by two operators twice. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) and BlandAltman were used for evaluating accuracy and reliability(p<0.05). Results: Excellent intrarater and good interobserver reliability values were found for linear measurements from CBCT images, with only one exception, interforame width, between observers in volume rendering images. Measurements performed on multiplanar reconstructed images were more accurate than the measurements in volume rendering compared to the gold standard. Conclusion: Linear measurements on multiplanar images of 0.2 and 0.4-voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. A protocol with less exposure, without compromising the diagnosis becomes feasible, because an increased voxel resolution did not result in greater accuracy of the measurements and potentially provides increased patient radiation exposure.
ASSUNTO(S)
cone-beam computed tomography mandible mandíbula orthodontics ortodontia tomografia computadorizada de feixe cônico
Documentos Relacionados
- Comparison between 3D volumetric rendering and multiplanar slices on the reliability of linear measurements on CBCT images: an in vitro study
- Avaliação de doses referenciais obtidas com exames de tomografia computadorizada de feixe cônico adquiridos com diferentes tamanhos de voxel
- Comparação entre imagens obtidas de telerradiografia lateral convencional, e imagens de tomografia computadorizada de feixe conico, na região da sinfise mentoniana
- Validity and reproducibility of cephalometric measurements obtained from 2D and 3D cone beam computed tomography images reconstructed
- Evaluation of simulated mandibular condyle bone using cone beam computed tomography