PERFORMANCE INDICES TO DESIGN A MULTICOMPONENT BATCH DISTILLATION COLUMN USING A SHORTCUT METHOD
AUTOR(ES)
Narvaes-Garcia, A., Zavala-Loria, J. C., Vilchiz-Bravo, L. E., Rocha-Uribe, J. A.
FONTE
Braz. J. Chem. Eng.
DATA DE PUBLICAÇÃO
2015-06
RESUMO
AbstractIn this paper, three quality or performance indices (Luyben's capacity factor, total annual costs, and annual profit) were applied for the design of a batch distillation column working at variable reflux. This work used the Fenske-Underwood-Gilliland short-cut method to solve a problem of four components (benzene, toluene, ethyl-benzene, and ortho-xylene) that needed to be separated and purified to a mole fraction of 0.97 or better. The performance of the system was evaluated using distillation columns with 10, 20, 30, 40 and 50 theoretical stages with a boil-up vapor flow set at 100 kmol/h. It was found that the annual profit was the best quality index, while the best case for variable reflux was the column with 50 stages. It was confirmed that the best case always required a reflux ratio close to the minimum.
Documentos Relacionados
- Simple multicomponent batch distillation procedure with a variable reflux policy
- Nonlinear dynamic modeling of multicomponent batch distillation: a case study
- Optimal design of beam-column connections of plane steel frames using the component method
- ETHANOL DEHYDRATION IN PACKED DISTILLATION COLUMN USING GLYCEROL AS ENTRAINER: EXPERIMENTS AND HETP EVALUATION
- REALIGNED MODEL PREDICTIVE CONTROL OF A PROPYLENE DISTILLATION COLUMN