Monitoring fibroblast behavior in tissue culture with an applied electric field.
AUTOR(ES)
Giaever, I
RESUMO
Mammalian fibroblasts have been cultured on evaporated gold electrodes subjected to an alternating electric field at 4000 Hz. The system consists of a large (approximately equal to 2 cm2) and a small (approximately equal to 3 X 10(-4) cm2) electrode bathed in tissue culture medium. The applied electric field produces a voltage drop at the boundary between the solution and the small electrode of a few mV at a current density of a few mA/cm2. The small population of cells that attach and spread on this electrode have a marked effect on the measured impedance and also cause it to fluctuate with time. The amplitude of these fluctuations is greatly reduced by cytochalasin B (10 microM), suggesting they are a consequence of cell movement.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=345299Documentos Relacionados
- Dynamic aspects of amphibian neurite growth and the effects of an applied electric field.
- The direction of growth of differentiating neurones and myoblasts from frog embryos in an applied electric field.
- Interaction of rabbit C-reactive protein with phospholipid monolayers studied by microfluorescence film balance with an externally applied electric field.
- Cochlear outer hair cell bending in an external electric field.