Lamella sedimentation: alternative for treatment of overflow sewage - study in ETE Martim de Sá (Caraguatatuba/SP). / Decantação acelerada: alternativa para o tratamento de vazão excedente de esgoto - estudo na ETE Martim de Sá (Caraguatatuba/SP).

AUTOR(ES)
DATA DE PUBLICAÇÃO

2010

RESUMO

This study was motivated by the need to treat high wastewater influent exceeding in sewage treatment plants, which occurs on days of heavy rain. The central hypothesis of this study is that the physical-chemical process to treat dilute sewage overflow, it can be advantageous with respect to increased capacity and expansion of biological systems. The research was conducted in ETE Martim de Sá (SABESP), located in Caraguatatuba / SP, where the sewage is treated by sequencing batch reactor. It was studied the variation of the flow of wastewater during the rainy season, and the operation of the batch. Furthermore, it was evaluated the use of coagulation, flocculation and sedimentation in plate settler with application of aluminium sulfate, ferric chloride and cationic polymer in a pilot plant, after the testing of bench scale apparatus in Jar Test. Monitoring the inflow showed that on days of rainfall and bypass, the maximum flow was 220 L/s, up to 6 times the dry weather average flow. For this situation, the physico-chemical process may become a promising alternative, due to its ability to work under high flow rates in smaller facilities. In tests to evaluate the physical-chemical treatment was used two kinds of raw sewage: 50 and 100 mg/L BOD, overflow rate used in the plated settling tank was 76.82 m³/m² / day. The best dosage of chemical used to treat the raw sewage BOD of 50 mg/L was 40 mg/L ferric chloride plus 0.5 mg/L of cationic polymer, resulting in average effluent with BOD of 26 mg/L. For the raw sewage of the range BOD of 100 mg/L, 60 mg/L ferric chloride was the best dosage with an average BOD of effluent equal to 44 mg/L. For this range of work is recommended to provide for the application of polymer. This research concluded that it is possible to comply with the legal standard of treated sewage with physical-chemical treatment, also produced evidence that can help in the economic evaluation for the implementation of this technology in parallel with the activated sludge system in hydraulic overload situations. However, analysis of the flow diagram of operation of the station with the sequencing batch reactor, indicated that it is possible to make the treatment of flow of 220 L/s by the biological process. Therefore, is recommend the implementation of physical-chemical treatment only if after the test-scale operation of the batches with the flow rate of 220 L/s, the biological treatment doesnt meet the established standards.

ASSUNTO(S)

esgoto diluído lodos ativados em bateladas sequenciais sequencing batch reactor plated settling tank decantador laminar physical-chemical treatment dilute sewage tratamento físico-químico

Documentos Relacionados