Iron distances in hemoglobin: comparison of x-ray crystallographic and extended x-ray absorption fine structure studies.
AUTOR(ES)
Fermi, G
RESUMO
A comparison is presented of the structures obtained around the iron atom in deoxyhemoglobin (Hb). The data come from extended x-ray absorption fine structure (EXAFS) studies of the iron, which gave Fe-porphyrin nitrogen distances of 2.06 +/- 0.01 A, and from the most recent high-resolution x-ray crystallographic study, which gave exactly the same distance--2.06 +/- 0.02 A. The distance of Fe above the plane of the porphyrin nitrogens was 0.38 +/- 0.04 A from the crystallographic study; this value is not far from the upper limit of the distances 0.20 +/- (0.10)0.20 A calculated from the EXAFS experiment by triangulation. These distances above the nitrogen plane are shorter than those estimated in the earliest x-ray structures.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=299030Documentos Relacionados
- On extended x-ray absorption fine structure studies of hemoglobin.
- Selenol binds to iron in nitrogenase iron-molybdenum cofactor: an extended x-ray absorption fine structure study.
- Determination of the iron-sulfur distances in rubredoxin by x-ray absorption spectroscopy.
- Structures of bromoalkanes' photodissociation in solution by means of ultrafast extended x-ray absorption fine-structure spectroscopy
- Extended x-ray absorption fine structure studies of a retrovirus: equine infectious anemia virus cysteine arrays are coordinated to zinc.