Influência das características das substâncias húmicas aquáticas na eficiência da coagulação com o cloreto férrico
AUTOR(ES)
Sloboda, Eliane, Vieira, Eny Maria, Dantas, Angela Di Bernardo, Di Bernardo, Luiz
FONTE
Química Nova
DATA DE PUBLICAÇÃO
2009
RESUMO
The aim of this study was to verify the influence of the apparent molecular size of aquatic humic substances on the effectiveness of coagulation with ferric chloride. Coagulation-filtration tests using jar test and bench-scale sand filters were carried out on samples of water with true color of approximately 100 Hazen units, prepared with aquatic humic substances of different molecular sizes (F1: < 0.45 µm, F2: 100 kDa - 0.45 µm, F3: 30 - 100 kDa and F4': < 30 kDa). For the water samples with lower apparent molecular size fractions, greater dosages of coagulant was needed to remove the color around 5.0 Hanzen units, mainly because these water samples contain higher concentrations of fulvic acids, which exhibited a larger number of negatively-charged groups.
Documentos Relacionados
- Influência das características das substâncias húmicas na eficiência da coagulação com sulfato de alumínio
- Influence of apparent molecular size from aquatic humic substances in the coagulation efficiency with aluminium sulfate and ferric chloride
- Influencia da pre-ozonização na coagulação-floculação utilizando o cloreto ferrico como coagulante
- Influence of apparent molecular size from aquatic humic substances in the efficiency of coagulation by aluminum hydroxychloride
- Influência das substâncias húmicas de sedimentos na biodisponibilidade de metais para o sistema aquático