INFLUENCE OF DIAMETER AND GEOMETRY IN THE TAPPING OF THE PILOT HOLE IN PEDICLE SCREWS
AUTOR(ES)
Defino, Helton Luiz Aparecido
FONTE
Coluna/Columna
DATA DE PUBLICAÇÃO
2019-03
RESUMO
RESUMO Objetivo: Avaliar o torque de inserção e a força de arrancamento de cada parafuso com diferentes diâmetros e machos. Métodos: Foram utilizados no estudo blocos de poliuterano com orifício piloto de 2,7mm, sendo feito um grupo experimentais com 5 blocos sendo avaliado o torque de inserção com torquímetro e avaliado o arrancamento de cada parafuso de parafusos Globus 5,5mm e 6,5mm. Resultados: A comparação do torque de inserção nos parafusos de 5,5mm entre a utilização de orifício piloto sem macheamento e o macheamento com diâmetro inferior ao diâmetro do parafuso (4,5mm) e rosca diferente, e com o macheamento com diâmetro igual do parafuso (5,5mm) e com rosca igual ou diferente apresentou diferença estatística com maior valor do torque de inserção no grupo em que o macheamento não foi realizado. Na força de arrancamento do parafuso 5.5mm o não macheamento do orifício piloto apresentou diferença estatística com o mesmo diâmetro do parafuso (5,5mm) e rosca diferente do parafuso. A força de arrancamento no parafuso 6,5mm foi maior no grupo em que o orifício piloto não foi macheado utilizando o teste não paramétrico de Kruskal Wallis com nível de significância adotado (p < 0,05) na comparação dos grupos. Conclusões: O macheamento do orifício piloto diminuiu o torque de inserção e resistência ao arrancamento do parafuso pedicular influenciando a fixação com macheamento com o mesmo diâmetro do parafuso e desenho de rosca diferente.ABSTRACT Objective: To evaluate the insertion torque and the pulling force of each screw with different diameters and tap. Methods: Polyurethane blocks with a pilot hole of 2.7 mm were used in the study. An experimental group with 5 blocks was formed, the insertion torque was evaluated with a torque meter, and the pullout strength of each Globus screw of 5.5 mm and 6.5 mm was assessed. Results: The comparison of the insertion torque on the 5.5 mm screws with pilot hole without tapping and with a smaller diameter than that of the screw (4.5 mm) and a different thread, and with the tapping with the same diameter as that of the screw (5.5 mm) and equal or different thread presented a statistical difference with a higher value of the insertion torque in the group in which the tapping was not performed. As for the pulling force of the 5.5 mm screw, the non-tapping of the pilot hole resulted in statistical difference with the same diameter of the screw (5.5 mm) and with a different thread of the screw. The pullout force on the 6.5 mm screw was higher in the group where the pilot hole was not tapped according to the non-parametric Kruskal-Wallis test, with significance level of p <0.05 in the comparison of the groups. Conclusions: Pilot hole tapping reduced insertion torque and pullout resistance of the pedicle screw influencing the fixation with tapping with the same screw diameter and different thread design.
Documentos Relacionados
- Use of a Customized Three-dimensional Guide in Preparing the Pilot Pedicle Hole in Spinal Deformities
- EFFECTS OF PILOT HOLE DIAMETER ON SCREW-DRIVING TORQUES IN MEDIUM DENSITY FIBERBOARD
- Biomechanical study of the sacroiliac fracture fixation with titanium rods and pedicle screws
- Comparing the Clinical Success Rate of Self-Drilling and Self-Tapping Mini-screws in the Retraction of Maxillary Anterior Teeth
- The Influence of Thread Tap Mismatch on Pedicle Screw Pullout Strength