Hemagglutination-Inhibition Test in Rhinovirus Infections of Volunteers
AUTOR(ES)
Reed, Sylvia E.
RESUMO
The hemagglutination-inhibition (HI) test for antirhinovirus antibody was carried out on paired sera from volunteers inoculated with rhinovirus type 3 or type 4 (RV4). The HI test gave results which paralleled the neutralization test and was at least as sensitive as a microneutralization method for detection of serotype-specific antibody. Although high levels of HI antibody in the serum were associated with protection from infection, in the case of RV4 low serum HI antibody levels did not necessarily imply susceptibility to challenge with small doses of virus. HI activity could be measured in concentrated nasal-washing fluids, and this antibody also seemed relevant to protection against infection.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=422799Documentos Relacionados
- Anti-Immunoglobulin G Hemagglutination-Inhibition Test for Influenza
- Use of Formalinized Sheep Erythrocytes in the Rubella Hemagglutination-Inhibition Test
- Identification of Enteroviruses by Hemagglutination-Inhibition
- Microtiter Hemagglutination-Inhibition Test for the Detection of Encephalomyocarditis Virus Antibodies
- Rubella hemagglutination-inhibition test: false-positive reactions in sera contaminated with bacteria.