Hearing AID prescription based on audiometric thresholds and auditory steady state responses / Ajustes das características eletroacústicas do aparelho de amplificação sonora individual com base em limiares auditivos tonais e resposta auditiva de estado estável

AUTOR(ES)
DATA DE PUBLICAÇÃO

2009

RESUMO

The impossibility for obtaining behavioral auditory data in children with hearing loss brings the necessity of applying objective tests as auditory steady state responses (ASSR) in order to evaluate the auditory thresholds. The objective of this study was to verify the differences found on the selection of the eletroacoustic characteristics of the hearing aid (AASI) based on the auditory thresholds, obtained by the auditory steady state responses (ASSR) in comparison with the same procedure realized, based on audiometric thresholds: A total of 28 people with sensorineural hearing loss were studied: group A comprised 10 adults (average age 46,3 years) and group B comprised 18 children (average age 10,38 years). The prescriptive method applied was Desired Sensation Level (DSL) i/o version 4.1. The individualized measurement of RECD was applied as acoustic transformer. Three different programs were generated considering the audiometric thresholds on the frequencies from 0,25 to 6kHz (complete tonal program- ProTC), the audiometric thresholds just on the frequencies 0,5, 1, 2 and 4 kHz (tonal program- ProT) and the auditory thresholds obtained by the ASSR on the frequencies 0,5, 1, 2 and 4 kHz (electrophysiological program ProE). The verification of the amplification was realized by a coupler of 2cc. The evaluation of speech recognition in noise (group A and B) and the judgment of sound quality (group A) was performed. The results showed that the Real Ear Aided Response prescribed (REAR P) were higher for the program based on the auditory thresholds estimated by the ASSR. The differences were significant, for all the levels of intensity tested, for the frequencies 0,5, 1, 2 and 2 kHz in group A and in all the frequencies in group B. The difference between REAR P and the REAR measured in coupler of 2cc (REAR M) was lower than 1,4dB for all the frequencies and intensities studied, for groups A and B. Differences were not found between the REAR M obtained on the ProTC and ProT. The results for REAR M obtained on the ProE were higher than the ones obtained on the programs ProTC and ProT. Significant differences were not found in the evaluation for the speech perception in adults. For children, significant differences were found for S/N on the ProE when compared to the program ProTC and ProT. On the evaluation of the sound quality, the results showed worse judgment of the dimensions evaluated, on the ProE. However, a significant difference was found for auditory comfort dimension. The outcomes of the present study shows that the auditory threshold obtained by the ASSR can be employed for the determination of the electroacoustic characteristics of the hearing aids in adults and children.

ASSUNTO(S)

auxiliares de audição perda auditiva auditory thresholds limiar auditivo deficiente auditivo potenciais evocados hearing loss evokad potentials aurally disabled hearing aids

Documentos Relacionados